E6582233
B-11
2
2
<Examples of connections when an external power supply is used>
Note 4) Be sure to connect 0V of external power supply and CC terminal of the inverter.
P24
CC
Note 4)
24V
DC
F
Output
24V
DC
OUT
NO
Input
Inverter
Programmable
controller
P24
Common
24V
DC
OFF
(
f127
=
200
)
CC
F
24V
DC
Output
Inverter
24V
DC
ON
(
f127
=
100
)
24V
DC
OUT
NO
Input
Programmable
controller
Input
Input
Output
Common
Common
Output
Common
Source (Positive) logic
f127
=
100
Sink (Negative) logic
f127
=
200