E6582233
C-3
3
3.1.1
How to run and stop
[Example of a
setting procedure]
Panel operation
LED display
Operation
Displays the operation frequency (operation stopped).
(When standard monitor display selection
=
[Operation frequency])
Displays the first basic parameter [History (
)].
Turn the setting dial, and select "
".
Press the center of the setting dial to read the parameter value.
(Standard default:
).
Turn the setting dial to change the parameter value to
(terminal block).
Press the center of the setting dial to save the changed parameter.
and the parameter set value are displayed alternately.
(1) Run and stop using the panel keypad (
=
)
Use the
and
keys on the panel keypad to start and stop the motor.
: Motor runs.
: Motor stops.
☆
The direction of rotation is determined by the setting of parameter
(forward run, reverse run
selection). (
: forward run,
: reverse run)
☆
To switch between forward run and reverse run from the extension panel (option), the parameter
(forward run, reverse run selection) needs to be set to
or
. (Refer to section 5.7)
(2) RUN / STOP by means of an external signal to the terminal board (
=
):
Sink (Negative) logic
Use external signals to the inverter terminal board to start and stop the motor.
Frequency
ON
OFF
F-CC
Slow down
and stop
F
Short
and terminals: run forward
Open and terminals: slow down and stop
CC
F
CC
MODE
RUN
STOP
RUN
STOP