5.3 Setting
acceleration/deceleration time
:
Automatic acceleration/deceleration
:
Acceleration time 1
:
Deceleration time 1
Function
1) For acceleration time 1
programs the time that it takes for the inverter output frequency to go
from 0Hz to maximum frequency
.
2) For deceleration time 1
programs the time that it takes for the inverter output frequency to go
from maximum frequency
to 0Hz.
5.3.1 Automatic
acceleration/deceleration
This automatically adjusts acceleration and deceleration time in line with load size.
=
* Adjusts the acceleration/deceleration time automatically within the range of 1/8 to 8 times as long as the
time set with the
or
, depending on the current rating of the inverter.
=
* Automatically adjusts speed during acceleration only. During deceleration, speed is not adjusted
automatically but reduced at the rate set with
.
Output
frequency (Hz)
Deceleration
time
Acceleration
time
When load is small
Time
[sec]
0
Shorten acceleration/deceleration time
Deceleration
time
Acceleration
time
When load is large
Output
frequency (Hz)
Time
[sec]
0
Lengthen acceleration/deceleration time
Set
(automatic acceleration/deceleration) to
or
.
[Parameter setting]
Title Function
Adjustment range
Default setting
Automatic acceleration/deceleration
0: Disabled (manual setting)
1: Automatic
2: Automatic (only at acceleration)
0
☆
When automatically setting acceleration/deceleration time, always change the acceleration/deceleration
time so that it conforms to the load. The acceleration/deceleration time changes constantly with load
fluctuations. For inverters that require a fixed acceleration/deceleration time, use the manual settings
(
,
).