6.1.3 Setting a parameter using the guidance function (
auf
)
auf
: Guidance function
[Parameter setting]
Title
Function
Adjustment range
Default setting
auf
Guidance function
0:-
1: -
Note 1
2: Preset speed guidance
3: -
Note 1
4: Motor 1&2 switching operation guidance
5: Motor constant setting guidance
0
Note1) 1 and 3 are for manufacturer's settings. Do not change the settings.
Guidance function (
auf
):
The guidance function refers to the special function of calling up only functions necessary to set up the inverter in
response to the user’s needs. When a purpose-specific guidance is selected, a group of parameters needed for the
specified application (function) is formed and the inverter is switched automatically to the mode of setting the group
of parameters selected. You can set up the inverter easily by simply setting the parameters in the group one after
another. The guidance function (
auf
) provides five purpose-specific guidance.