E6582175
F-99
6
6.27 Acceleration/deceleration time 2 and 3
6.27.1 Selecting acceleration/deceleration patterns
f502
: Acceleration/deceleration 1 pattern
f506
: S-pattern lower-limit adjustment amount
f507
: S-pattern upper-limit adjustment amount
Function
These parameters allow you to select an acceleration/deceleration pattern that suits the intended use.
Title
Function
Adjustment range
Default setting
f502
Acceleration/deceleration 1 pattern
0: Linear, 1: S-pattern 1, 2: S-pattern 2
0
f506
S-pattern lower-limit adjustment
amount
0-50 (%)
10
f507
S-pattern upper-limit adjustment
amount
0-50 (%)
10
1)
Linear acceleration/deceleration
A general acceleration/
deceleration pattern.
This pattern can usually be
used.
2)
S-pattern 1 acceleration/deceleration
Select this pattern to accelerate/decelerate the motor rapidly to an output frequency above 60Hz or to
minimize the shocks applied during acceleration/deceleration. Perfect for conveyance machinery.
Actual acceleration time
×
%
×
%
Time [s]
Output frequency [Hz]
0
Maximum frequency
Set frequency
Output frequency
[Hz]
Maximum frequency
Time [s]
0
Actual deceleration time
Maximum frequency
Set frequency
×
%
×
%
Time [s]
Output frequency [Hz]