E6582175
D-14
4
4.5
EASY key function
psel
: EASY key mode selection
f750
: EASY key function selection
f751
to
f782
: Easy setting mode parameter 1 to 32
[Parameter setting]
Title
Function
Adjustment range
Default setting
psel
EASY key mode selection
0: Standard setting mode at power on
1: Easy setting mode at power on
2: Easy setting mode only
0
f750
EASY key function selection
0: Easy / standard setting mode switching function
1: Shortcut key
2: Local / remote key
3: Monitor peak / minimum hold trigger
4, 5: -
0
Easy / Standard setting mode
switching function (
f750
=
0
): Default setting
It is possible to switch between standard mode and easy setting mode when you push the EASY key while the
inverter is stopping.
Standard setting mode is selected when the power is turned on at default setting.
The way parameters are read out and displayed varies according to the mode selected.
Easy setting mode
Allows pre-registration (easy setting mode parameters) of frequently changed parameters and reading of only
registered parameters (maximum of 32 types).
In the Easy setting mode, the EASY key lamp lights.
Standard setting mode
Standard setting mode in which all parameters are read out.
[How to read out parameters]
Use the EASY key
to change between
Easy setting mode and Standard setting mode, and then press the MODE
key to enter the setting monitor mode.
Turn the setting dial to read the parameter.
The relation between the parameter and the mode selected is shown below.
Function
It is possible to switch between standard mode and easy setting mode using the EASY key. (default setting)
Up to 32 arbitrary parameters can be registered to easy setting mode.
The EASY key can select following four functions.
• Easy / Standard setting mode switching function
• Shortcut key function
• Local / Remote switching function
• Peak hold function