TRST-A10/TRST-A15 POS Printer OPOS Control Application User’s Manual
TOSHIBA TEC CORPORATION EAA-02450
35
UnKnownRetryCount. To identify UnKnown from device not connected
(Power OFF) for retries, a time is set in milliseconds.
This module resets the device hardware to recover from UnKnown and
identifies UnKnown from device not connected (Power OFF) depending
on whether or not the device can be connected within a specified time
of period. When this item is not contained in the registry list, no values
are given, or something other than a numeric value is specified, 4000
(4 sec.) is selected as a default.
DebugLogLevel
Specifies a level for recording a log in a file specified by DebugLogFile.
0:
Log is not output.
1:
Level where a log is recorded mainly at a time of error
2:
Level where OPOS operations can be traced using a log.
DebugLogFile
Specifies a log file with path which records OPOS operations. If a
folder does not exist, no log is kept.
(*1)
Used by the TRSTA1S/TRSTA1P
(*2)
Used by the TRSTA1S
(*3)
Used by the TRSTA1U
Table 14 TRSTA1x POS Printer Control – Common Registries for Single/Dual Printers