Q9 Plus ASD Installation and Operation Manual
111
V/I Input Point 2 Rate
Program
Torque
Setpoints
This parameter is used to set the gain and bias of the
V/I
input terminal when
the
V/I
terminal is used as the control input while operating in the
Torque
Control
mode.
Torque Control is accomplished by establishing an associated
V/f
output pattern
for a given
V/I
input level.
This parameter sets
V/I Input Point 2 Rate
and is the output torque value that
is associated with the setting of
V/I Input Point 2 Setting
when operating in
the
Torque Control
mode.
This value is entered as 0% to 250% of the rated torque.
See
V/I Input Point 1 Rate
(
F205
) for additional information on this
parameter.
Direct Access Number — F206
Parameter Type —
Numerical
Factory Default —
100.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 250.00
Units — %
Frequency Mode 2
Program
Fundamental
Standard Mode Selection
This parameter is used to set the source of the frequency command signal to be
used as
Frequency Mode 2
in the event that
Frequency Mode 1
is disabled or
if
Frequency Mode 2
is set up as the primary control parameter.
See
F004
and
F200
for additional information on this parameter.
Settings:
1 — V/I
2 — RR
3 — RX
4 — Panel Keypad
5 — RS485 2-Wire (EOI)
6 — RS485 4-Wire (Terminal Board)
7 — Communication Option Board
8 — RX2
9 —
Option V/I
10 — UP/DOWN Frequency
11 — Optional RP Pulse Input
12 — Optional High-Speed Pulse Input
Direct Access Number — F207
Parameter Type —
Selection List
Factory Default —
V/I
Changeable During Run —
No
Frequency Mode Priority Switching Frequency
Program
Fundamental
Standard Mode Selection
This parameter
establishes a threshold frequency that will be used as a reference
when determining when to switch the output frequency control source from the
Frequency Mode 1
setting to the
Frequency Mode 2
setting.
See
F200
for additional information on this parameter.
Direct Access Number — F208
Parameter Type —
Numerical
Factory Default —
(ASD-Dependent)
Changeable During Run —
Yes
Minimum — (ASD-Dependent)
Maximum — Maximum Freq. (
F011
)
Units — Hz
F206
F208
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com