Q9 Plus ASD Installation and Operation Manual
225
Input Function Target 2
Program
My Function
My Function Unit 7
This parameter plays a role in the setup of the
My Function
feature by
selecting the functionality of the programmable
Input Function Target 2
terminal.
This setting assigns the function of the programmable
Input Function Target 2
terminal to any one of the user-selectable functions listed in
Table 12 on pg.
238
,
Table 13 on pg. 239
, or
Table 15 on pg. 242
.
See
F977
for additional information on this parameter.
Direct Access Number — F955
Parameter Type —
Selection List
Factory Default —
0 (Disabled)
Changeable During Run —
Yes
Input Function Command 2
Program
My Function
My Function Unit 7
This parameter is used to assign a user-selected logical operator to two user-
selected
Input Function Target
variables, enable a counter/timer function, or
perform a hold/reset function.
Table 16 on pg. 244
lists the available selections. Their use and selection
requirements are described in an example at
F977
.
Direct Access Number — F956
Parameter Type —
Selection List
Factory Default —
0 (NOP)
Changeable During Run —
Yes
Input Function Target 3
Program
My Function
My Function Unit 7
This parameter plays a role in the setup of the
My Function
feature by
selecting the functionality of the programmable
Input Function Target 3
terminal.
This setting assigns the function of the programmable
Input Function Target 3
terminal to any one of the user-selectable functions listed in
Table 12 on pg.
238
,
Table 13 on pg. 239
, or
Table 15 on pg. 242
.
See
F977
for additional information on this parameter.
Direct Access Number — F957
Parameter Type —
Selection List
Factory Default —
0 (Disabled)
Changeable During Run —
Yes
Output Function Assigned
Program
My Function
My Function Unit 7
This parameter plays a role in the setup of the
My Function
feature by
selecting the functionality of the
Output Function Assigned
terminal.
This setting assigns the function of the programmable
Output Function
Assigned
data location to one of the functions listed in the
Input Setting
field
of
Table 13 on pg. 239
.
Settings:
0 – 3099
See the
My Function Instruction Manual
(P/N E6581335) and
F977
for
additional information on this parameter.
Direct Access Number — F958
Parameter Type —
Selection List
Factory Default —
0 (Disabled)
Changeable During Run —
Yes
F955
F958
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com