Q9 Plus ASD Installation and Operation Manual
265
Table 24. 460-Volt UL Type-1/IP-20 Chassis Standard Ratings Table.
Model
Number
100% Output
Current
Continuous
Overload Current
110% for 60
Seconds
Input Voltage
3-Ph 50/60
± 2 Hz
Output Voltage
3-Ph Variable
Frequency
Typical
Motor HP
4015
2.1 A
2.3 A
380 – 480 VAC
(±10%)
Input Voltage
Level (Max.)
1.0
4025
3.4 A
3.7 A
2.0
4035
4.8 A
5.3 A
3.0
4055
7.6 A
8.4 A
5.0
4080
11.0 A
12.1 A
7.5
4110
14.0 A
15.4 A
10
4160
21.0 A
23.1 A
15
4220
27.0 A
29.7 A
20
4270
34.0 A
37.4 A
25
4330
40.0 A
44.0 A
30
4400
52.0 A
57.2 A
40
4500
65.0 A
71.5 A
50
4600
77.0 A
84.7 A
60
4750
96.0 A
106 A
75
410K
124 A
136 A
100
412K
156 A
172 A
125
415K
180 A
198 A
150
420K
240 A
264 A
200
425K
302 A
332 A
250
430K
361 A
397 A
300
435K
414 A
455 A
350
440K
477 A
525 A
400