C. While still connected to the VP 300, enter the mailbox number of mailbox B. This
should be the same as the extension number of phone B. Does the VP 300 respond with
the prompt, “Thank you. Just a moment…”?
NO
➧
Determine the cause and correct the problem before continuing.
D. After a short interval, does the VP 300 respond with, “Extension EXT-B is in use.
Please leave a private message at the tone…”?
NO
➧
Determine the cause and correct the problem before continuing.
E.
Dial
9 9
to exit from the VP 300. Hang up phone A and phone B.
6.
EXTERNAL TRUNK CALL TO THE VP 300
This test verifies that the VP 300 correctly processes calls from trunks that have been
auto-terminated to the VP 300 hunt group. Be sure to test all such trunk groups.
☞
1-800 (InWATS) lines can be tested individually, even if they are bands from other
areas, by using plant test numbers. Get these numbers from the CO if you do not
already know them.
A. From phone A, call outside of the PBX and back in on a trunk that auto-terminates to
the VP 300. Does the VP 300 answer with the greeting configured for the trunk?
NO
➧
Determine the cause and correct the problem before continuing.
B. From the terminal connected to the VP 300, enter the PS command. Does the port that
answered show FWD state?
NO
➧
Determine the cause and correct the problem before continuing.
C. Dial
9 9
to exit the VP 300. From the VP 300 terminal, busy out the VP 300 port that
answered the call. Use the command
TE C 1 x
where x is the port number
D. Repeat steps A through C for each VP 300 port until all the ports are busied out. This
is to confirm that each VP 300 port can answer a trunk call.
E.
To release all VP 300 ports from the FWD condition, from the VP 300 terminal, use
the command
TE C 2
7.
EXTERNAL CALL TO A RING-NO-ANSWER EXTENSION
This test verifies that the VP 300 correctly processes an external call that reaches a
ring-no-answer (RNA) extension.
A. Make sure phone B is on-hook.
B. From phone A, call outside of the PBX and back in on a trunk that auto-terminates to
the VP 300. Does the VP 300 answer with the greeting configured for the trunk?
Toshiba VP Systems
Release 6.1
February, 1993
MITEL SX-2000 ADAPTIVE INTEGRATION
10.3-41
Summary of Contents for VP 300
Page 2: ......
Page 10: ......
Page 14: ......
Page 20: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 52: ...Toshiba VP Systems Release 6 1 February 1993 2 14 Installation and Maintenance Manual ...
Page 56: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 146: ......
Page 312: ...Toshiba VP Systems Release 7 1 July 1994 ...
Page 314: ......
Page 444: ......
Page 496: ......
Page 542: ......
Page 598: ...Toshiba VP Systems Release 6 1 February 1993 ...
Page 600: ...Toshiba VP Systems Release 6 1 February 1993 ...