AFM 400 Hz
AFM 400 Hz
Carrier
1.3 MHz (L ch)
1.7 MHz (R ch)
Item
No.
Mode
Time
Record
Contents
Audio signal
Video signal
Color bar
Mono Scope
2 MHz (recorded
on CH-A only)
Color bar
30% White
1 kHz
3 kHz
Record each
400 Hz & 7 kHz
for 1min 30 s in
3 cycles.
3 kHz
No signal
*Check and adjustment of Servo circuit.
*Check and adjustment of Video circuit.
*Check and adjustment of Audio circuit.
*Check and adjustment of Servo circuit.
Notes: 1. This signal is used for tape running
adjustment.
2. Set tracking control to center position
except linearity adjustment.
3. When making linearity adjustment
(S, T-guide roller), set tracking control to
the position where envelope obtains max.
*Check and adjustment of Servo circuit.
*Check and adjustment of Video circuit.
*Check and adjustment of Servo circuit.
Notes :1. This signal is used for tape running
adjustment also.
2. Set tracking control to center.
When making linearity adjustment, set
tracking control to the position where
envelope obtains max..
1-1
1-2
1-3
1-4
1-5
SP
SP
SP
EP
(SLP)
EP
(SLP)
10 min
10 min
9 min
5 min
5 min
Item
No.
Mode
Time
Record
Contents
Video signal
Notes : This signal is used for tape running
adjustment.
Set tracking control to center position.
*Check and adjustment of Hi-Fi Audio circuit.
(Set tracking control to the position when Audio FM
output level obtains max.)
Notes : This signal is used for tape running
adjustment also.
Set tracking control to center position.
2-1
2-2
2-3
SP
SP
SP
5 min
5 min
5 min
Hi-Fi audio
signal (recorded
on video track)
3 MHz (recorded
on CH-A only)
Color bar
Color bar
Alignment tape specifications
(1) ST-N1
(2) ST-NF (Hi-Fi Audio (AFM) adjustment)