Direct Access Parameter Information
W7B ASD Installation & Operation Manual
96
https://www.toshiba.com/tic/
BIN Input Point 2 Torque
Program
Torque
Setpoints
This parameter is used to set the direction, gain, and bias of the BIN
binary input terminals when these terminals are used as the control input
while operating in the Torque Control mode.
This is accomplished by establishing an associated V/f output pattern for
a given BIN binary input and motor load.
See
for additional information on this setting.
This parameter sets BIN Torque Reference Setpoint 2 and is entered as
-250 to +250% of the rated torque.
Direct Access Number —
F233
Parameter Type —
Numerical
Factory Default — +
100.0
Changeable During Run —
Yes
Minimum — -250.0
Maximum — +250.0
Units — %
PG Reference Point 1
Program
Frequency
Speed Reference Setpoints
This parameter is used to set the direction, gain, and bias of the PG
input terminal when it is used as the Speed/Direction control input. The
PG input signal is a pulse count originating from a shaft-mounted
Encoder.
Note:
The PG input terminal may be used with the ASD-Multicom
option board only.
Perform the following setup to allow the system to receive a binary control
input:
•
Program
Fundamental
Standard Mode Selection
Command Mode (any setting).
•
Program
Fundamental
Standard Mode Selection
Frequency Mode 1 (11 = Pulse Input Option).
•
Provide a Run command (F or R).
The settings that determine the direction, gain, and bias of the PG input
are:
•
PG Speed Frequency Setpoint 1
)
,
•
the PG input pulse count that represents PG Speed Frequency
Setpoint 1 (
),
•
PG Speed Frequency Setpoint 2
)
, and
•
the PG input pulse count that represents PG Speed Frequency
Setpoint 2 (
).
Once set, as the PG input pulse count changes, the directional
information or the output frequency of the drive will vary in accordance
with the above settings.
This parameter sets the PG input pulse count that represents Reference
Setpoint 1 (frequency) (direction/speed). The range of values for this
parameter is -100 to +100% of the PG input pulse count range.
Note:
Additional application-specific PG settings may be performed
from the following path: Program
Feedback Parameters
PG
Settings
Direct Access Number —
F234
Parameter Type —
Numerical
Factory Default —
0.0
Changeable During Run —
Yes
Minimum — -100.0
Maximum — +100.0
Units — %
Frequency Settings
Summary of Contents for W7 DN-57442-006
Page 1: ...ADJUSTABLE SPEED DRIVES W7 DN 57442 006 INSTALLATION OPERATION MANUAL June 2020 ...
Page 2: ......
Page 3: ...Document Number 57442 006 Date June 2020 W7 ASD Installation and Operation Manual ...
Page 4: ......
Page 60: ......
Page 221: ......