S-Pattern Acceleration Upper-Limit Adjustment
Program
Special
ACC/DEC Special
This parameter sets the upper-limit frequency of S-Pattern 1 and 2.
Direct Access Number —
F507
Parameter Type —
Numerical
Factory Default —
25.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 50.00
Units — %
Acceleration/Deceleration Time Lower Limit
Program
Special
ACC/DEC Special
This parameter sets the lower-limit of the Accel/Decel time.
Direct Access Number —
F508
Parameter Type —
Numerical
Factory Default —
0.10
Changeable During Run —
Yes
Minimum — 0.01
Maximum — 10.00
Units — Seconds
Acceleration Time 3
Program
Special
ACC/DEC 1-4 Settings
This parameter specifies the time for the drive to go from 0.0 Hz to the
Maximum Frequency for the Acceleration 3 profile. The accel/decel
pattern may be set using
. The minimum accel/decel time may be
set using
Note:
An acceleration time shorter than the load will allow may cause
nuisance tripping and mechanical stress to loads.
Automatic Accel/Decel and Stall settings may lengthen the acceleration
time.
Direct Access Number —
F510
Parameter Type —
Numerical
Factory Default —
(ASD-Dependent)
Changeable During Run —
Yes
Minimum —
Maximum — 6000
Units — Seconds
Deceleration Time 3
Program
Special
ACC/DEC 1-4 Settings
This parameter specifies the time for the drive to go from the Maximum
Frequency to 0.0 Hz for the Deceleration 3 profile.
The accel/decel pattern may be set using
. The minimum accel/
.
Note:
A deceleration time shorter than the load will allow may cause
nuisance tripping and mechanical stress to loads.
Automatic Accel/Decel and Stall settings may lengthen the deceleration
time.
Direct Access Number —
F511
Parameter Type —
Numerical
Factory Default —
(ASD-Dependent)
Changeable During Run —
Yes
Minimum —
Maximum — 6000
Units — Seconds
Acceleration/Deceleration Pattern 3
Program
Special
ACC/DEC 1-4 Settings
This parameter enables a user-selected preprogrammed output profile
that controls the acceleration and deceleration pattern for the Accel/
Decel 3 parameter.
Settings:
0 — Linear
1 — S-Pattern 1
2 — S-Pattern 2
Direct Access Number —
F512
Parameter Type —
Selection List
Factory Default —
Linear
Changeable During Run —