Direct Access Parameter Information
W7B ASD Installation & Operation Manual
https://www.toshiba.com/tic/
91
RX2 Reference Point 1
Program
Torque
Setpoints
This parameter is used to set the direction, gain, and bias of the RX2
input terminal when this terminal is used as the control input while
operating in the Speed Control or the Torque Control mode.
Note:
The RX2 input terminal may be used with the ASD-Multicom
option board only.
Perform the following setup to allow the system to receive control input at
the RX2 input terminal:
•
Program
Fundamental
Standard Mode Selection
Command Mode Selection (0 = Terminal Board).
•
Program
Fundamental
Standard Mode Selection
Frequency Mode 1 (4 = RX2).
•
Provide a Run command (F or R).
Gain and Bias Settings
When operating in the Speed Control mode, the settings that determine
the direction, gain, and bias of the RX2 terminal are:
•
RX2 Speed Frequency Setpoint 1
,
•
the RX2 input signal level that represents RX2 Speed Frequency
Setpoint 1 (
),
•
RX2 Speed Frequency Setpoint 2
, and
•
the RX2 input signal level that represents RX2 Speed Frequency
Setpoint 2
).
When operating in the Torque Control mode, the settings that determine
the direction, gain, and bias of the RX2 terminal are:
•
Torque Reference Setpoint 1
(
)
,
•
the RX2 input signal level that represents the RX2 Torque
Reference Setpoint 1 (
),
•
Torque Reference Setpoint 2
(
)
, and
•
the RX2 input signal level that represents Torque Reference
Setpoint 2 (
).
Once set, as the RX2 input voltage changes, the directional information,
the output frequency, or the output torque of the drive will vary in
accordance with the above settings.
This parameter sets the RX2 input level that represents RX2 Reference
Setpoint 1 (frequency) (direction/torque/frequency). This value is entered
as -100 to +100% of the -10 to +10 VDC RX2 input signal range.
The input signal may be trimmed using
(Bias) and
Direct Access Number —
F222
Parameter Type —
Numerical
Factory Default —
0.0
Changeable During Run —
Yes
Minimum — -100.0
Maximum — 100.0
Units — %