Direct Access Parameter Information
W7B ASD Installation & Operation Manual
https://www.toshiba.com/tic/
115
Heavy-Load Torque During Deceleration in the Forward Direction
Program
Special
Crane/Hoist Load
During forward deceleration, this parameter establishes the threshold
torque level that is used to determine if the Light-Load High-Speed
(
) operation may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Direct Access Number —
F337
Parameter Type —
Numerical
Factory Default —
100
Changeable During Run —
Yes
Minimum — 0
Maximum — 250
Units — %
Switching Load Torque During Reverse Run
Program
Special
Crane/Hoist Load
While running in reverse, this parameter establishes the threshold torque
level that is used to determine if the Light-Load High-Speed (
operation may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Direct Access Number —
F338
Parameter Type —
Numerical
Factory Default —
50
Changeable During Run —
Yes
Minimum — 0
Maximum — 250
Units — %
Heavy-Load Torque During Acceleration in the Reverse Direction
Program
Special
Crane/Hoist Load
During reverse acceleration, this parameter establishes the threshold
torque level that is used to determine if the Light-Load High-Speed
(
) operation may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Direct Access Number —
F339
Parameter Type —
Numerical
Factory Default —
(ASD-Dependent)
Changeable During Run —
Yes
Minimum — 0
Maximum — 250
Units — %
Heavy-Load Torque During Deceleration in the Reverse Direction
Program
Special
Crane/Hoist Load
During reverse deceleration, this parameter establishes the threshold
torque level that is used to determine if the Light-Load High-Speed
(
) operation may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Direct Access Number —
F340
Parameter Type —
Numerical
Factory Default —
100
Changeable During Run —
Yes
Minimum — 0
Maximum — 250
Units — %
Frequency for Automatic High-Speed Operation at Light-Load
Program
Special
Crane/Hoist Load
This parameter establishes the speed that the ASD will ramp to when
operating in the Light-Load High-Speed mode.
Direct Access Number —
F341
Parameter Type —
Numerical
Factory Default —
80
Changeable During Run —
Yes
Minimum — 0.00
Maximum — Max. Freq.
(
Units — %
Summary of Contents for W7 DN-57442-006
Page 1: ...ADJUSTABLE SPEED DRIVES W7 DN 57442 006 INSTALLATION OPERATION MANUAL June 2020 ...
Page 2: ......
Page 3: ...Document Number 57442 006 Date June 2020 W7 ASD Installation and Operation Manual ...
Page 4: ......
Page 60: ......
Page 221: ......