Direct Access Parameter Information
W7B ASD Installation & Operation Manual
https://www.toshiba.com/tic/
119
Selection of Number of PG Input Phases
Program
Feedback
PG Settings
This parameter determines the type of information that is supplied by the
phase encoder.
Settings:
1 — Single Phase
2 — Two Phase
Direct Access Number —
F368
Parameter Type —
Selection List
Factory Default —
Two Phase
Changeable During Run —
No
PG Disconnection Detection
Program
Feedback
PG Settings
This parameter Enables/Disables the system’s monitoring of the PG
connection status when using encoders with line driver outputs.
Settings:
1 — Disabled
2 — Enabled
Direct Access Number —
F369
Parameter Type —
Selection List
Factory Default —
Disabled
Changeable During Run —
Yes
Electronic Gear Setting (pulses/rotation)
Direct Access Number —
F370
Program
Feedback
PG Settings
Parameter Type —
Numerical
This parameter sets the number of pulses per revolution when using a
shaft-mounted encoder and the PG Option Board for closed loop speed
control.
Factory Default —
1000
Changeable During Run —
Yes
Minimum — 100
Maximum — 4000
Position Loop Gain
Program
Feedback
PG Settings
This parameter provides a divisor for the pulse input when operating in
the Pulse Control mode.
Direct Access Number —
F371
Parameter Type —
Numerical
Factory Default —
4.00
Changeable During Run —
Yes
Minimum — 0.0
Maximum — 100.0
Position Completion Range
Program
Feedback
PG Settings
During a deceleration ramp, this parameter sets a speed range that must
be attained before the Stop command may be executed.
Direct Access Number —
F372
Parameter Type —
Numerical
Factory Default —
100
Changeable During Run —
Yes
Minimum — 1
Maximum — 4000