Direct Access Parameter Information
W7B ASD Installation & Operation Manual
160
https://www.toshiba.com/tic/
ASD Number
Program
Communications
Communication Settings
This parameter plays a role in the setup of the communications network
by assigning an identification (ID) number to each ASD in the
communications network.
The communications network includes other ASDs and Host/Control
computers that monitor the status of the ASD(s), transfers commands,
and loads or modifies the parameter settings of the ASD.
Changes made to this parameter require that the power be cycled (off
then on) for the changes to take effect.
Direct Access Number —
F802
Parameter Type —
Numerical
Factory Default —
0
Changeable During Run —
Yes
Minimum — 0
Maximum — 255
Communications Time-Out (RS232/RS485)
Program
Communications
Communication Settings
This parameter plays a role in the setup of the communications network
by setting the time that no activity may exist over the communications
link before the link is severed (Time-Out).
The communications network includes other ASDs and Host/Control
computers that monitor the status of the ASD(s), transfers commands,
and loads or modifies the parameter settings of the ASD.
Changes made to this parameter require that the power be cycled (off
then on) for the changes to take effect.
Direct Access Number —
F803
Parameter Type —
Numerical
Factory Default —
0
Changeable During Run —
Yes
Minimum — 0
Maximum — 100
Units — Seconds
Communication Time-Out Action (RS232/RS485 and TTL)
Program
Communications
Communication Settings
This parameter plays a role in the setup of the communications network
by determining the action to be taken in the event of a time-out (Time-
Out Action).
The communications network includes other ASDs and Host/Control
computers that monitor the status of the ASD(s), transfers commands,
and loads or modifies the parameter settings of the drive.
Changes made to this parameter require that the power be cycled (off
then on) for the changes to take effect.
Settings:
0 — RS232/RS485=No action/TTL=No action
1 — RS232/RS485=Alarm/TTL=No action
2 — RS232/RS485=No action/TTL=Alarm
3 — RS232/RS485=Alarm/TTL=Alarm
4 — RS232/RS485=Trip/TTL=Alarm
5 — RS232/RS485=No action/TTL=Trip
6 — RS232/RS485=No action/TTL=Trip
7 — RS232/RS485=Alarm/TTL=Trip
8 — RS232/RS485=Trip/TTL=Trip
Direct Access Number —
F804
Parameter Type —
Selection List
Factory Default —
RS232/RS485 and
nTTL = Trip
Changeable During Run —
Yes