35
EOI Remote Mounting
The
WX9 ASD
may be controlled from a remotely mounted EOI. For safety and application-specific
reasons, some ASD installations will warrant that the operator not be in the vicinity during operation or
that the
EOI
not be attached to the ASD housing. The
EOI
may be mounted either with or without the
optional
Remote Mounting Kit
(P/N ASD-MTG-KITQ9), which allows for remote
EOI
placement and
easier cable routing.
The
EOI
can operate up to 9 feet away from the ASD. An
EOI
extender cable is required for remote
mounting and is included with
Remote Mounting Kit
or can be ordered through the TIC Customer
Support Center.
Remote Mounting Hardware
•
Remote Mounting Kit (optional) — P/N ASD-MTG-KITQ9
•
LCD Cable, 9 ft. — P/N 76268
Remote Mounting Installation Precautions
Install the unit securely in a well-ventilated area that is out of direct sunlight. The ambient temperature
rating for the display module is 14° to 104° F (-10° to 40° C).
•
Select a mounting location that is easily accessible by the user.
•
Avoid installation in areas where vibration, heat, humidity, dust, metal particles, or high levels or
electrical noise (EMI) are present.
•
DO NOT
install the unit where it may be exposed to flammable chemicals or gases, water, solvents,
or other fluids.
•
Turn on the power only after securing the front cover of the ASD.
Remote Mounting Using the Mounting Kit
Note:
for the dimensions and the item locations referenced in steps
1 – 7.
1. At the
EOI
mounting location, mark the 4.60” by 4.50” hole and the four 11/32” screw holes.
2. Cut the 4.60” by 4.50” rectangular mounting hole.
3. Drill the four 11/32” screw holes for the
Bezel Plate
mount.
4. Attach and secure the
Bezel Plate
to the front side of the mounting location using the four 10-32 hex
nuts, #10 split lock washers, and the #10 flat washers.
5. Remove the
Front Panel Assembly
of the ASD — using a flathead screwdriver, release the upper
retaining tabs of the EOI panel. Then pivot the EOI assembly away from the ASD and lift
).
6. Remove the
Display Module
from the
Front Panel Assembly
of step 5 — discard the assembly.
7. Attach and secure the
Display Module
to the front side of the
Bezel Plate
using the four 6-32 x
5/16” pan head screws, and the #6 split lock washers.
When installing the
Display Module
into the
Bezel Plate
, ensure that the left side of the display is
inserted first with the top and bottom catches securely in place (adjacent to the Phillips screws at
underside of display). This ensures the proper alignment and electrical connection of the CNX
connector of the
Display Module
PCB. Then gently hold the display in place while securing the
Phillips mounting screw.
8. Install the
Front Panel Connector Assembly
to the ASD (see
).
9. Connect the
Extender Cable
from the
EOI
to the
Front Panel Assembly
.
Summary of Contents for WX9 ASD