Torque Command Mode Selection
Program
Torque
Torque Speed Limiting
This parameter specifies whether the torque command function is to be used in
one direction or both (F/R).
Settings:
0 — Fixed Direction
1 — F/R Permitted
Direct Access Number — F429
Parameter Type —
Selection List
Factory Default —
Fixed Direction
Changeable During Run —
No
Speed Limit (torque = 0) Center Value Reference Selection
Program
Torque
Torque Speed Limiting
The system has the ability to limit the amount that the speed may vary as a
function of a changing load while operating in the
Torque Control
mode. This
parameter sets the input terminal that will be used to control the allowable
speed variance.
If
Setting (F431)
is selected, the value setting at
is used.
Settings:
0 — Disabled
1 — VI/II
2 — RR
3 — RX
4 — RX2
5 — Setting (F431)
Direct Access Number — F430
Parameter Type —
Selection List
Factory Default —
Disabled
Changeable During Run —
No
Speed Limit (torque = 0) Center Value
Program
Torque
Torque Speed Limiting
The system has the ability to limit the amount that the speed may vary as a
function of a changing load while operating in the
Torque Control
mode. This
parameter sets the targeted speed.
The plus-or-minus value for this setting may be set at
Direct Access Number — F431
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — Maximum Freq. (
Units — Hz
Speed Limit (torque = 0) Band
Program
Torque
Torque Speed Limiting
The system has the ability to limit the amount that the speed may vary as a
function of a changing load while operating in the
Torque Control
mode.
This parameter sets a plus-or-minus value for the
Speed Limit Torque Level
).
Direct Access Number — F432
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — Maximum Freq. (
Units — Hz
Speed Limit (torque = 0) Recovery Time
Program
Torque
Torque Speed Limiting
The system has the ability to limit the amount that the speed may vary as a
function of a changing load while operating in the
Torque Control
mode. This
parameter sets the response time of the system to torque change requirements.
Direct Access Number — F433
Parameter Type —
Numerical
Factory Default —
0.20
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 2.50
Units — Seconds