WX9 ASD Installation and Operation Manual
151
Deceleration Time 2
Program
Special
Acc/Dec (1 - 4) Settings
This parameter specifies the time in seconds for the drive to go from the
Maximum Frequency
to 0.0 Hz for the
Deceleration (Dec) 2 Profile
. The
Acceleration/Deceleration (Acc/Dec)
pattern may be set using
S-Curve Acc/
Dec Pattern 1
F502)
. The minimum
Acc/Dec
time may be set using
Acc/Dec
Time Lower Limit
(
.
This setting is also used to determine the deceleration rate of the
UP/DOWN
Frequency
functions.
Note:
A deceleration time shorter than the load will allow may cause
nuisance tripping and mechanical stress to loads.
Automatic Acceleration/Deceleration, Stall
, and
Ridethrough
settings
may lengthen the deceleration time.
Direct Access Number — F501
Parameter Type —
Numerical
Factory Default —
(ASD-Dependent)
Changeable During Run —
Yes
Minimum —
Maximum — 6000
Units — Seconds
S-Curve Acceleration/Deceleration Pattern 1
Program
Fundamental
Acc/Dec 1 Settings
Program
Special
Acc/Dec (1 - 4) Settings
This parameter enables a user-selected preprogrammed output profile that
controls the acceleration and deceleration pattern for the
Acceleration/
Deceleration (Acc/Dec) 1
parameter.
Settings:
0 — Linear
1 — S-Pattern 1
2 — S-Pattern 2
The figures below provide a profile of the available
Acc/Dec
patterns.
Direct Access Number — F502
Parameter Type —
Selection List
Factory Default —
Linear
Changeable During Run —
Yes
S-Pattern 2
acceleration and
deceleration decreases the rate of
change above the base frequency.
Linear
acceleration and
deceleration is the default pattern
and is used on most applications.
S-Pattern 1
is used for applications
that require quick acceleration and
deceleration. This setting is also
popular for applications that require
Summary of Contents for WX9 ASD