– 60 –
RAS-13YAH-E, RAS-13YAH-ES
2-ST2T
Ø
4
´
12
2-ST1T
Ø
4
´
10
Remove
7-ST1T
4
´
10
No.
Part name
Procedure
Remarks
Q
Common
procedure
1) Stop the operation of air-conditioner, and disconnect
the power cord from the AC supply.
2) Remove E-parts cover.
(2- ST1T Ø4 x 10
l
)
3) Remove the cord clamp (2- ST2T Ø4 x 12
l
) and
remove the connecting cable.
4) Remove the front cabinet.
(7- ST1T Ø4 x 10
l
with nylon washer)
• Pull the front lower portion toward you, and remove
it pulling out upward.
R
Capacitor for
compressor
1) Perform the process
Q
above.
1) Remove the fixing screw of the capacitor band.
(1- ST2T Ø4 x 8
l
)
2) Remove the cable connected to the terminal.
S
Capacitor for
fan motor
1) Perform the process
Q
above.
1) Remove the fixing screw.
(1- ST2T Ø4 x 8
l
)
2) Remove the cable connected to the terminal.
T
Overload
relay
1) Perform the process
Q
above.
2) Remove Fastons of leads.
3) Remove the fixing screw.
(1- ST2T Ø4 x 10
l
)
4) Pull OL-Holder up and remove Overlord relay from
OL-Holder.
U
Thermostat
bimetal
1) Perform the process
Q
above.
2) Remove terminal cover of compressor.
3) Remove thermo holder and pull thermostat bimetal
up.
4) Remove Fastons of leads.
1-ST2T
f
4
´
10
1-ST2T
f
4
´
8
OL-Holder
1-ST2T
f
4
´
8
Compressor
Thermostat
bimetal
Thermo
holder