background image

OPERATION AND STORAGE

TO TURN ON THE HEATER

1. Open the cylinder valve after checking that  the connections are all tight and that there 
are no gas leaks
2. Press in and then turn the appliance control valve knob in an anti clockwise direction to 
the Pilot position
3. With the appliance control valve in the Pilot position continue to press the control valve 
knob in and whilst doing so press the ignitor button several times until the Pilot burner 
ignites. Once the pilot burner has ignited release the control knob 

Note:

 

If a new cylinder has been fitted it may take a minute for the air in the hose to be cleared 
before the pilot burner ignites.
If the pilot burner does not ignite repeat Step 3

4. After the Pilot Burner ignites turn the appliance control valve to the full position and 
leave it at that setting for 5 minutes before turning the knob to the desired heat setting 

TO TURN OFF THE HEATER

1. Press and turn the appliance control knob to the Off position
2. Close the cylinder valve 

1. Always close the cylinder valve when the heater is not in use,  or if the heater 
malfunctions when in use,or if there is a gas leak.
2. Store the cylinder in cool dry well ventilated place away from any other flammable 
materials
3. Protect the heater from damage by covering it when not in use.

Off- Shut down position 
Hi - Max temperature setting 
Lo - Min temperature setting

Variable control knob

Pointer

LO

W

H

IG

H

T

O

LI

P

 OFF

IG

N

IT

E

P

us

h

to

tur

n

- 6 -

Summary of Contents for 16/DK1027

Page 1: ...ING HAZARDOUS FIRE OR EXPLOSION MAY RESULT IF INSTRUCTIONS ARE IGNORED It is the consumer s responsibility to see that the heater is properly assembled installed and taken care of Failure to follow in...

Page 2: ...turned o until it has cooled down Do not paint the radiant screen control panel or top canopy re ector The control compartment burner and circulation air passageways must be kept clean Frequent cleani...

Page 3: ...OF CONTENTS Caution 1 Heater Stand and Location 2 Gas Requirements 2 Leakage Test 2 Operation and Storage 3 Cleaning and Care 4 Parts and Specifications 4 Assembly Parts and Procedures 6 Problems Chec...

Page 4: ...otective device removed for servicing the heater must be replaced before operating the heater Adults and children should stay away from high temperature surface to avoid burns or clothing ignition Chi...

Page 5: ...ours are stored HEATER STAND AND LOCATION GAS REQUIREMENTS LEAKAGE TEST Gas connections on the heater are leak tested at the factory prior to shipment A complete gas tightness check must be performed...

Page 6: ...he pilot burner ignites If the pilot burner does not ignite repeat Step 3 4 After the Pilot Burner ignites turn the appliance control valve to the full position and leave it at that setting for 5 minu...

Page 7: ...corrosive Remove debris from the burner to keep it clean and safe for use Cover the burner unit with the optional protective cover when the heater is not in use PARTS AND SPECIFICATIONS 1360 mm 880 m...

Page 8: ...M8 X 15 Qty 2 AA M8 Flange nut Qty 2 Burner assembly N O I T P I R C S E D T R A P QUANTITY A Flame screen guard 1 B 1 Cylinder Housing C 1 D Base E Wheel 1 1 Philips screwdriver with medium blade Sp...

Page 9: ...bracket with wheel to the base 2 Use 4 pcs M5x8mm screws nuts to join the cylinder housing to the base ASSEMBLY PROCEDURES C CC AA BB x 2 M8 x 15 mm Bolts M8 Flange Nut x 2 FF Wrench x 1 Hardware Used...

Page 10: ...8mm screw to join the burner head and cylinder housing body 4 Use the M6 Dome Nut to connect the two half safety guards to the burner head Hardware Used CC EE x 4 x 1 Philips screwdriver Screw M5 X 8...

Page 11: ...re that the rubber seal on the end of the regulator is in place and is in good condition The cylinder valve thread is a left hand thread and the regulator handwheel must be turned in an anti clockwise...

Page 12: ...ace Thermocouple Burner will not light Pilot light assembly bent or not in correct location Place pilot light in correct position and retry PROBABLE CAUSE 12 Distributed by D K Gas Appliances PO Box 3...

Reviews: