Other risks 

 
Even when the power tool is used as prescribed, it is not possible to eliminate all residual 

risk factors: 

a.  Health defects resulting from the emission of vibrations if the power tool is used 

for a longer period of time or if it is not properly managed and maintained. 

b.  Injury and property damage from broken accessories suddenly breaking. 

 

Caution 

This power tool produces an electromagnetic field during operation. 

This field can, in some circumstances, interfere with active or passive 

medical implants. 
To reduce the risk of serious injury, we recommend that individuals with 

medical implants consult their physician before using this power tool. 
If the cord is damaged or cut during work, do not touch the cord, immediately unplug the 

tool. Never use the machine with a damaged cord. 
The machine must not be damp and must not be used in a humid environment. 
 

Attention 

Safe working with this machine is only possible when the operating or 

safety information is fully read and the instructions contained therein are 

strictly followed. 
 

Technical data 

 

Data sheet 

Power 

1050W 

Voltage 

220-240V 

Frequency 

50 / 60Hz 

No-load speed 

900 / min 

Impact rate 

4000 / min 

Cement drilling capacity 

28mm 

Steel drilling capacity 

13mm 

Wood drilling capacity 

40mm 

 
 

 

Summary of Contents for TH110286

Page 1: ...1 V ROTARY HAMMER...

Page 2: ...Keep the cord away from heat or oil e When using a power tool outdoors use an extension cord suitable for outdoor use f If it is unavoidable to use the tool in a humid location use a residual current...

Page 3: ...could result in a dangerous situation e Store power tools out of the reach of children and do not allow anyone unfamiliar with the tool to use it f Maintain power tools Check for misalignment or bindi...

Page 4: ...control can cause personal injury Hold the power tool by the insulated gripping surfaces when performing an operation where the cutting attachment may contact hidden wires or its own cord Cutting att...

Page 5: ...uce the risk of serious injury we recommend that individuals with medical implants consult their physician before using this power tool If the cord is damaged or cut during work do not touch the cord...

Page 6: ...ed do not have to be included in the standard delivery Set up Before using Be careful of hidden power lines or gas and water pipes Check the work area with devices such as metal detectors Always use t...

Page 7: ...auxiliary handle Auxiliary handle You can obtain a safe position when working with the tool rotated by holding the auxiliary knob Loosen and turn the handle attachment counterclockwise To tighten the...

Page 8: ...uitable tool With the locking sleeve removed pull the new cap until it seats firmly on the tool holder and the locking sleeve can slide forward again If the machine should fail despite the care taken...

Page 9: ...9 Exploded view...

Page 10: ...10 ROTARY HAMMER...