background image

 

Additional security warnings 

 

  Wear ear protectors. Exposure to noise can cause hearing loss. 

  Use auxiliary handles, if supplied with the tool. Loss of control can cause personal 

injury. 

  Hold power tool by insulated gripping surfaces when performing an operation 

where the cutting accessory may contact hidden wiring or its own cord. 

  The cutting accessory coming into contact with a live cable could cause an 

electric shock to the operator. 

  Always route the cable to the rear, away from the machine. 

  Do not carry the machine by the cable. 

  When working with the machine, always hold it firmly with both hands and stand 

firm. 

  During breaks in work or when the tool is not in use (for example, changing work 

tools, repairs, cleaning, adjustment), disconnect the tool from the mains. 

  Unqualified people cannot use this tool. 

  Keep tool accessories out of the reach of children. 

  Use only original accessories recommended by the manufacturer. 

 

Other risks 

 
Even when the power tool is used as prescribed, it is not possible to eliminate all residual 

risk factors: 

a.  Health defects resulting from vibration emission if the power tool is used for a 

longer period of time or if it is not managed and maintained properly. 

b.  Injuries and property damage due to broken fixtures breaking suddenly. 

 

Caution 

This power tool produces an electromagnetic field during operation. 

This field can, in some circumstances, interfere with active or passive 

medical implants. 
To reduce the risk of serious injury, we recommend that persons with 

medical implants consult their physician before using this power tool. 
If the cable is damaged or cut during work, do not touch the cable, immediately unplug 

the tool. Never use the machine with a damaged cable. 
The machine must not be damp and must not be used in a humid environment. 
 

Attention 

Safe operation of this machine is only possible when the operating or safety 

information is fully read and the instructions contained therein are strictly 

followed. 
 

Summary of Contents for TH115326

Page 1: ...1 v ROTARY HAMMER ...

Page 2: ...the cable away from heat or oil e When using a power tool outdoors use an extension cord suitable for outdoor use f If using the tool in a damp location is unavoidable use a Residual Current Device RCD protected supply to reduce the risk of electric shock 3 Personal security a Always stay alert watch what you are doing and use common sense when using the tool b Do not use a power tool if you are t...

Page 3: ...f moving parts breakage of parts and any other conditions that may affect the operation of power tools If it is damaged have the power tool repaired before using it Many accidents are caused by poorly maintained power tools g Keep cutting tools sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control 5 Service a Have your power to...

Page 4: ... accessories recommended by the manufacturer Other risks Even when the power tool is used as prescribed it is not possible to eliminate all residual risk factors a Health defects resulting from vibration emission if the power tool is used for a longer period of time or if it is not managed and maintained properly b Injuries and property damage due to broken fixtures breaking suddenly Caution This ...

Page 5: ...t description 1 Spare chuck 2 Drill chuck 3 Dust cap 4 Lock sleeve 5 Auxiliary handle 6 Unlock button 7 Operating mode selection switch 1 8 Operating mode selection switch 2 9 ON OFF switch Note The machine is designed for impact drilling in concrete brick and stone It is also suitable for non impact drilling in wood metal ceramics and plastic Note 2 Not all accessories illustrated or described ma...

Page 6: ...ll the locking sleeve back and hold it while removing the bit Only use bits that fit the screw heads Set up Power on press the ON OFF switch Power off release the ON OFF switch Work instructions Drilling overload stop If the bit jams or binds the rotation of the bit is interrupted Due to the forces that occur you should always hold the machine with both hands and take a safe stance The machine mus...

Page 7: ...n the switch to the direction Maintenance Sharpening of chiseling tools With sharp insert tools good working performance and long service life are achieved Therefore sharpen the chisel regularly Sharpen the tool on a grinding wheel eg alumina oxide with a constant supply of water For safe operation Always keep the machine and the ventilation slots clean Clean the tool holder daily Replacing the du...

Page 8: ...ispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local authority for information on available collection systems If electrical appliances are disposed of in landfills hazardous substances can seep into the groundwater and enter the food chain harming your health and well being Recycle raw materials instead of disposing of them as waste The...

Page 9: ...9 ROTARY HAMMER ...

Reviews: