A-16
Register Description
Type
Access
Note
255.1
Number of Math Operations
Uint16
Read/Write
8
255.2
Number of Bit Operations
Uint16
Read/Write
9
255.3
Number of Compare Operations
Uint16
Read/Write
10
255.4
Number of Array Operations
Uint16
Read/Write
11
255.5 Enable
Period
Descriptors
Uint16 Read/Write 22
255.6
Enable Math Descriptors
Uint16
Read/Write
22
255.7
Enable Bit Descriptors
Uint16
Read/Write
22
255.8
Enable Compare Descriptors
Uint16
Read/Write
22
255.9
Enable Array Descriptors
Uint16
Read/Write
22
255.10
Number of Select Operations
Uint16
Read/Write
23
255.11
Enable Select Descriptors
Uint16
Read/Write
22
255.12
Number of Lag Operations
Uint16
Read/Write
24
255.13
Enable Lag Descriptors
Uint16
Read/Write
22
255.14
Number of Lead Operations
Uint16
Read/Write
25
255.15
Enable Lead Descriptors
Uint16
Read/Write
22
255.16
Number of Queue Operations
Uint16
Read/Write
26
255.17 Enable
Queue
Descriptors
Uint16 Read/Write 22
255.18
Number of Ramp Operations
Uint16
Read/Write
27
255.19
Enable Ramp Descriptors
Uint16
Read/Write
22
255.20
Number of Pulse Operations
Uint16
Read/Write
28
255.21 Enable
Pulse
Descriptors
Uint16 Read/Write 22
255.22
Number of Limit Operations
Uint16
Read/Write
29
255.23
Enable Limit Descriptors
Uint16
Read/Write
22
255.24
Number of Scale Operations
Uint16
Read/Write
30
255.25 Enable
Scale
Descriptors
Uint16 Read/Write 22
255.26
Number of PID Operations
Uint16
Read/Write
31
255.27
Enable PID Descriptors
Uint16
Read/Write
22
Operations Application Register Notes:
1.
Periodic Operations can be executed at a cyclic interval (such as every 5 seconds), at a specific
time of day (such as 8:00), or they can be triggered by another register. If the operation trigger
type in array 1 is 0 (Interval), the operation is executed at the interval specified by the
corresponding register in array 2. If the operation trigger type is 1 (Time), the operation is
executed at the time of day specified by the corresponding register in array 2. If the operation
trigger type is 2 (Triggered), the operation is executed each second if the register specified by
the corresponding register in array 0 is non-zero.
2.
Periodic Operations combine the capabilities of Math, Bit, Compare, and Array operations. The
registers in array 3 contain operation codes specifying the operation to be performed. The
registers in arrays 4 and 5 contain the operands of the operations. The registers in array 6
specify where the results of the operations will be placed. The following operation codes are
supported:
0 - No Operation
1 - R1 + R2 (Addition)
2 - R1 – R2 (Subtraction)
Summary of Contents for XRC6490
Page 1: ...2100802 001 AB TOTALFLOW XSeries Remote Controller User s Manual ...
Page 6: ...iv B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 10: ...viii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 19: ...1 5 Standard Enclosure Cont RC 6790 X Figure 1 2 Model XRC6790 Continued on Next Page ...
Page 41: ...1 27 Totalflow Input Output Modules Cont Figure 1 16 XRC6990 Inside View ...
Page 42: ...1 28 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 64: ...2 22 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 86: ...4 12 Replacing XRC 195 Board Cont Figure 4 5 XRC Board Connections ...
Page 88: ...4 14 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 112: ...5 24 12V Communication Supply Voltage Test Cont Figure 5 9 XRC 195 Communication Wiring ...
Page 292: ...A 176 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 340: ...B 48 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 342: ...C 2 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...