A-68
0.61 tubeCheckPoint
control Read/Write
14
0.62
Canadian Event Log Inhibit Flag
Read Only
15
0.63
Stop Logging Events
Read Only
16
0.64
Log in Gage Pressure
Read/Write
17
0.65
Log DP Check
Write Only
18
0.66
Reserved for Selectable Units
Read/Write
19
0.67
Reserved for Selectable Units
Read/Write
19/20
0.68
Reserved for Selectable Units
Read/Write
19
Tube Byte Register Usage Notes:
1.
Used for AGA-3 1985-Dynamic Factor Select Bits:
0x01, 1 /* Use Ftf */
0x02, 2 /* Use Y */
0x04, 4 /* Use Fr */
0x08, 8 /* Use Fa */
0x10, 16 /* Use Fpv */
0x20, 32 /* Use Fw (water vapor factor) */
0x40, 64 /* Use pipe tap equation */
0x80, 128 /* tap cfg supported (Set by FCU ) */
2.
Used only for AGA-3 1992-Static Factor Select Bits:
0x08 /* Use Live CD if set */
0x10 /* Use Fws (Faux:well stream) */
0x20 /* Static Pressure Tap is Upstream */
0x40
/* Supports switchable characteristics */
3.
Used only for AGA-3 1992 -Dynamic Factor Select Bits:
0x02, 2 /* Use Y */
0x10, 16 /* Use Fpv */
0x20, 32 /* Use Fw (water vapor factor) */
4.
Volume Calculation Type: 0 = NONE, 1=AGA-3 1985, 2=AGA-3 1992.
5.
Super-Compressibility Method: 0=NX19 with FIXED FT AND FP VALUES, 1=NX19 AUTO,
2=NX19 GRAVITY CO2 & N2, 3=NX19 CO2 & N2 & C1, 11=AGA-8 Gross, 12=AGA-8 Detail
6.
Characteristics Type: This was used in “Totalflow old database” format. This does not apply to
X-series, DB2 format.
7.
Live Analysis Configuration flags: 0=USE FIXED ANALYSIS, 1=USE LIVE ANALYSIS FROM
AIU, 2=USE LIVE ANALYSIS FROM OTHER PROTOCOL, 16=USE FIXED ANALYSIS ON
ERROR. USE FIXED ANALYSIS ON ERROR may be added to selections 1 or 2.
8.
Flow rate / Volume scale flags: 0=MCF for volumes, SCF/HR for flow rates; 1=MCF for volumes,
MCF/DAY for flow rates; 2=MMCF for volume, MCF/HR for flow rates; 3=MMCF for volumes,
MMCF/DAY for flow rates.
9.
Aux Contact 1 & 2 select bits low byte: 1=trip contact on low charger; 2=trip contact on Dp low;
4=trip contact on Dp high; 8=trip contact on Ap low; 16=trip contact on Ap high; 32=trip contact
on remote sense; 64=auto re-open; 128=trip contact on volume set-point. These registers can
also be set from 16-bit integer registers 1.10 and 1.11.
Summary of Contents for XRC6490
Page 1: ...2100802 001 AB TOTALFLOW XSeries Remote Controller User s Manual ...
Page 6: ...iv B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 10: ...viii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 19: ...1 5 Standard Enclosure Cont RC 6790 X Figure 1 2 Model XRC6790 Continued on Next Page ...
Page 41: ...1 27 Totalflow Input Output Modules Cont Figure 1 16 XRC6990 Inside View ...
Page 42: ...1 28 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 64: ...2 22 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 86: ...4 12 Replacing XRC 195 Board Cont Figure 4 5 XRC Board Connections ...
Page 88: ...4 14 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 112: ...5 24 12V Communication Supply Voltage Test Cont Figure 5 9 XRC 195 Communication Wiring ...
Page 292: ...A 176 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 340: ...B 48 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 342: ...C 2 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...