1-8
XRC General Specifications
Dimensions
XRC Model
Width
Height
Depth
6490
11.52” (292.61mm)
14.81” (376.17mm) 10.27”
(260.83mm)
6790
15.10” (383.54mm)
18.80” (477.52mm) 13.38”
(339.85mm)
6890
20.09” (510.29mm)
28.91” (734.31mm) 15.52”
(394.21mm)
6990
16.91” (429.51mm)
1
10.47” (265.93mm)
10.21” (259.33mm)
2
Installed Depth
XRC Model
Pipe Mounted
Direct Mounted
6490
12.75” (323.85mm)
11.00” (279.40mm)
6790
15.75” (400.05mm)
14.00” (355.60mm)
6890
18.01” (457.45mm)
16.26” (413.00mm)
Enclosure
XRC Model
Weight
(w/o battery)
Max
I/O Modules
Max
Battery Capacity
6490
8.86 lbs. (3.31k)
3
26 AH
6790
29.0 lbs. (13.17k)
6
42 AH
6890
45.5 lbs. (16.98k)
12
140 AH
6990
12.0 lbs. (5.44k)
14
30 AH
Humidity
0–95% Non-Condensing
Mounting
Wall, Pipe or Rack Mount
Operating Temp.
-40° F to 140° F (-40 to 60
°
C)
Certification (all
but 6990)
CSA/NRTL Class 1, Division 2, Groups C & D hazardous area
classification. (ATEX Zone 2 pending). XRC6990 is General Purpose
EMC
Requirements
EMMISSIONS:
European Regions:
•
EN55022 Class A Emissions (Radiated & Conducted)
North America Regions:
•
CFR 47, Part 15, Subpart B, Class A, FCC Emissions
•
ICES-003 Issue 2, Rev. 1, Class A ITE Emissions
IMMUNITY:
European Regions:
•
EN50082-1:98
Immunity
•
EN61000-4-2:95, ESD, ± 8 kV Air, ± 4 kV Contact
•
EN61000-4-3:95 RF Immunity, 10 V/m
•
EN61000-4-4:95 EFT, 1 kV
•
EN61000-5-5:95 Surge; 1 kV line to line, 2 kV line to
earth
•
EN61000-4-6:95 Conducted Susceptibility, 3 Vrms
•
EN610004-8:93 Power Frequency Magnetic Field 3
A/m
•
EN610004-11:94 Voltage DIP and interrupt
1
Enclosure width does not include mounting rail. Total width is 19” (482.6mm)
2 Enclosure depth does not include TFIO Modules mounted. Depth with Modules: 14.72” (373.89mm)
Summary of Contents for XRC6490
Page 1: ...2100802 001 AB TOTALFLOW XSeries Remote Controller User s Manual ...
Page 6: ...iv B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 10: ...viii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 19: ...1 5 Standard Enclosure Cont RC 6790 X Figure 1 2 Model XRC6790 Continued on Next Page ...
Page 41: ...1 27 Totalflow Input Output Modules Cont Figure 1 16 XRC6990 Inside View ...
Page 42: ...1 28 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 64: ...2 22 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 86: ...4 12 Replacing XRC 195 Board Cont Figure 4 5 XRC Board Connections ...
Page 88: ...4 14 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 112: ...5 24 12V Communication Supply Voltage Test Cont Figure 5 9 XRC 195 Communication Wiring ...
Page 292: ...A 176 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 340: ...B 48 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 342: ...C 2 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...