A-134
ARRAY.REGISTER
DESCRIPTION
USAGE
GROUP
NAME
7.63
Last Calc Cd
Read Only
None
7.64
Last Calc Cp
Read Only
None
7.65
Last Calc Cp_s
Read Only
None
7.66
Last Calc qm
Read Only
Base Mass
Flow
7.67
Last Calc Qv
Read Only
Base Volume
Flow
7.68
Today’s Accumulated Mass
Read Only
Total Mass
7.69
Today’s Contract Day
Accumulated Mass
Read Only
Total Mass
7.70
Yesterday’s Contract Day
Accumulated Mass
Read Only
Total Mass
7.71
Today’s Accumulated Energy
Read Only
Total Energy
7.72
Today’s Contract Day
Accumulated Energy
Read Only
Total Energy
7.73
Yesterday’s Contract Day
Accumulated Energy
Read Only
Total Energy
7.74
Current Ap
Read Only
Abs Pressure
7.75
Current Tf
Read Only
Temperature
7.76 Barometric
Pressure
Read/Write Barometric
7.77
Current Dp
Read Only
Diff Pressure
Tube Floating Point Register Notes:
1.
Static pressure values are in absolute or gauge depending on gauge pressure device selection.
See Tube Byte Register 0.55.
2.
Flow Rate Limits units depend on Flow rate / volume scale flags. See Tube Byte Register 0.42.
3.
The units for this group are dependent on the value of the heating select bit accesed via register
app.6.5. For a “0” the group is HV Volume, for “1” the group is HV Mass.
4.
LCP Integral – this is the square root of the static pressure * differential pressure / flowing
temperature. For Selectable Units this field is always calculated as:
static
pressure:
bar
diff
pressure:
mbar
temperature:
deg
Kelvin
5.
LCP Fip – for the current implementation Fip is calculated as follows:
Fip = xpt * sqrt_rgrav * sqrt(( 2 * Mair / Rgc ) * (1/Zba)) * Fpv
Where: xpt =
see note 4 above
Sqrt_rgrav = square root of the real specific gravity
Mair = 28.9625
Rgc
=
0.0831451
Zba = compressibility of air as entered by the user
Fpv = calculated super compressibility
Summary of Contents for XRC6490
Page 1: ...2100802 001 AB TOTALFLOW XSeries Remote Controller User s Manual ...
Page 6: ...iv B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 10: ...viii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 19: ...1 5 Standard Enclosure Cont RC 6790 X Figure 1 2 Model XRC6790 Continued on Next Page ...
Page 41: ...1 27 Totalflow Input Output Modules Cont Figure 1 16 XRC6990 Inside View ...
Page 42: ...1 28 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 64: ...2 22 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 86: ...4 12 Replacing XRC 195 Board Cont Figure 4 5 XRC Board Connections ...
Page 88: ...4 14 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 112: ...5 24 12V Communication Supply Voltage Test Cont Figure 5 9 XRC 195 Communication Wiring ...
Page 292: ...A 176 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 340: ...B 48 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 342: ...C 2 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...