A-136
ARRAY.REGISTER DESCRIPTION
USAGE
10.14
Last Calc Normal Octane
Read Only, mole %
Mole Percent
10.15
Last Calc Normal Nonane
Read Only, mole %
Mole Percent
10.16
Last Calc Normal Decane
Read Only, mole %
Mole Percent
10.17
Last Calc Oxygen
Read Only, mole %
Mole Percent
10.18
Last Calc Carbon Monoxide
Read Only, mole %
Mole Percent
10.19
Last Calc Hydrogen
Read Only, mole %
Mole Percent
10.20
Last Calc Argon
Read Only, mole %
Mole Percent
10.21
Last Calc Air
Read Only, mole %
Mole Percent
10.22
Last Calc Heavy
Hydrocarbons
Read Only, mole % Mole
Percent
10.23
Last Calc Heat Content
Read Only, BTU/SCF
See note 1)
10.24
Last Calc Specific Gravity
Read Only
None
The group depends on the heating value selected. For energy/mass the group is HVMass_grp. For
energy/volume the group is HVVolume_grp.
Tube Use File Units Get Registers (11.0 … 11.63):
This read only register returns the units string that a usefile group is currently set to. The format of
the command is app.11.group number. Where group number
range from “0” to MAX_GROUPS-1
(currently “63” for a usefile).
Tube Use File String Register (12.0 … 12.63):
This read only register returns the register number that will return the units a usefile group is
currently set. The format of the command is app.12.group number. Where group number
range from
“0” to MAX_GROUPS-1 (currently “63” for a usefile). A typical response would be app.11.group
number.
Tube Use File Units Get Registers (13.0 .. 13.63):
This read only register returns the group name, as a string, assigned to usefile group. The format of
the command is app.13.group number. Where group number
range from “0” to MAX_GROUPS-1
(currently “63” for a usefile).
Tube Use File Image Register (14.0 … 14.63):
This read/write register is use to set usefile image group units. The register numbers may range
from “0” to MAX_GROUPS-1 (currently “63” for a usefile). The register number is actually a use file
group number Data values entered into these register are transferred to use file upon execution of
register set command app.6.11=1.
Note: Executing the app.6.11=1 command will cause the
data base to be reset loosing all long term data in the tube application.
The command app.14.group number will return:
App.14.group
number=AA,BBCC,DDDD
Where: AA = group number in decimal
BB = conversion group number in decimal
CC = unit number in decimal
DDDD = the flag field in ascii-hex
On write the command must be entered as AA,BB,CC,DDDD exactly. The comma separator field is
important as well a each digit. The allowed ranges for each field is determined by the entries in the
Unit_Tab.dat file.
Tube Read/Write Use File Registers (array.15 … array.22):
Summary of Contents for XRC6490
Page 1: ...2100802 001 AB TOTALFLOW XSeries Remote Controller User s Manual ...
Page 6: ...iv B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 10: ...viii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 19: ...1 5 Standard Enclosure Cont RC 6790 X Figure 1 2 Model XRC6790 Continued on Next Page ...
Page 41: ...1 27 Totalflow Input Output Modules Cont Figure 1 16 XRC6990 Inside View ...
Page 42: ...1 28 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 64: ...2 22 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 86: ...4 12 Replacing XRC 195 Board Cont Figure 4 5 XRC Board Connections ...
Page 88: ...4 14 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 112: ...5 24 12V Communication Supply Voltage Test Cont Figure 5 9 XRC 195 Communication Wiring ...
Page 292: ...A 176 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 340: ...B 48 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 342: ...C 2 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...