During Setup & Programming:
 Pressing the Mode button
selects different flashing items. 
(Represented in 

dark black

)

Pressing the Up and Down
buttons will modify the flashing
selection.

Press the Mode button.
While holding the Mode,
press the Override button
for 2 seconds to enter Clock
Set screens.

Press both Mode and
Override buttons as
above to return to
normal operation.

Quick Start  

Set the Clock and Go

Page 5

     The thermostat is preprogrammed from the
     factory to operate 1 or 2 Stage equipment*  without
     the need for further programming.  To optimize the
     installation of this thermostat follow the instructions
     in the Advanced Setup section.

                

* The thermostat is not preprogrammed from the

                    factory to operate electric heat or heat pump systems.
                   To control these systems, follow the steps in the
                   Advanced Setup section, pages 12 & 13. 
          

buttons.

To adjust the

clock or Day use

Press

   I

I2:00

  2

Su

OVERRIDE

OVERRIDE

MODE

MODE

MODE

Summary of Contents for P374-2200FM

Page 1: ... Security Levels Energy Saving Smart Fan No Batteries Required Includes Locking Cover 1 For All Use with most Air Conditioning Heating Systems including 1 or 2 Stage Electric Cooling Gas Heating Heat Pump Electric or Hydronic Heat Both Commercial Residential Meets California Title 24 72 74 70 Am COOL HEAT AUTO Mo I2 00 P N P374 2200FM Replacement Components Division Carrier Corporation 11 98 TOTAL...

Page 2: ...noccupied ADVANCED SETUP ABOUT ADVANCED OPERATION WARRANTY Page 1 CAUTION Follow Installation Instructions before proceeding SET THERMOSTAT TO MODE OFF PRIOR TO CHANGING SETTINGS IN SETUP OR RESTORING FACTORY DEFAULTS P N P374 2200FM 2 3 5 6 8 12 17 23 Replacement Components Division Carrier Corporation 11 98 ...

Page 3: ...Front Panel Page 2 Liquid Crystal Display with Thermoglow Up Down Buttons Mode Button Override Button Heat or Cool Indicator Heat Red Cool Green Temperature Sensor Bubble 1 2 3 4 5 6 1 3 5 2 4 6 ...

Page 4: ...AM ON indicates the stored program is enabled to run Page 6 Clock with Day of the Week Indicates the current time and day This clock is also used to program the timer periods Page 5 Room Temperature Display Indicates the current room temperature Desired Set Temperature Indicates desired room temperature s Page 7 Display Page 3 1 2 1 5 1 3 6 7 10 9 8 4 4 11 1 1 88 88 88 unoccupied Program Fan On Se...

Page 5: ...cates constant continuous fan operation When Fan On is not lit indicates the fan will only operate when necessary to heat or to cool Page 12 Service Filter Indication Service Filter indicates when the filter should be serviced under normal conditions Appears after 0 1950 hours of blower operation adjustable Page 14 Locked Indication Locked appears after the right combination of buttons are pressed...

Page 6: ...mal operation Quick Start Set the Clock and Go Page 5 The thermostat is preprogrammed from the factory to operate 1 or 2 Stage equipment without the need for further programming To optimize the installation of this thermostat follow the instructions in the Advanced Setup section The thermostat is not preprogrammed from the factory to operate electric heat or heat pump systems To control these syst...

Page 7: ...s both heating and air conditioning systems are turned off AUTO will automatically select heat or cool based on room temperature demand Program On will activate the stored timer operation occupied unoccupied periods Select Mode Basic Operation Page 6 Press Press Press Press 70 69 Pm HEAT Mo I2 00 70 72 Pm COOL Mo I2 00 70 72 69 Pm COOL HEAT AUTO Mo I2 00 70 73 70 unoccupied ProgramOn Pm COOL HEAT ...

Page 8: ...mporarily With each successive push of the Override button the override timer will add 30 minutes until the maximum of 4 hours is reached Then the next press will zero out the override timer returning to unoccupied if there are no further button presses When in Override the Override icon and the Occupied 1 icon appear on the display The time of day clock alternates with the time remaining in overr...

Page 9: ...riod programming Continued Select the maximum of occupied periods to be used on any one day Typically 1 1 2 or 3 Adjust the cooling setpoint for occupied 1 Adjust the cooling setpoint for unoccupied periods Adjust the heating setpoint for occupied 1 35 99 35 99 35 99 MODE MODE MODE MODE MODE occupied 1 74 occupied COOL 1 74 72 Occupied COOL HEAT 1 85 unoccupied COOL ...

Page 10: ...occupied periods 35 99 Select the day for Occupied 1 Adjust the stop time for occupied 1 Select Occupied 1 to run on this day On or not to run this day Off Adjust the start time for occupied 1 M S Off On MODE MODE MODE MODE 55 unoccupied HEAT occupied Mo 1 occupied Am Start Mo 1 7 00 occupied Pm Stop Mo 1 6 00 occupied ON Mo 1 ...

Page 11: ...mode will copy the previous day s program and then will ask the same copy question again If yes is selected each time this routine will repeat until Saturday is copied to Sunday After Saturday is copied to Sunday the copy command is unavailable The copy command becomes available after the maximum of occupied periods are programed in a day This example uses 1 as the maximum occupied periods ever pr...

Page 12: ...ming steps are skipped Heat Cool setpoints for Occupied 1 are the same for every day of the week Heat Cool setpoints for Occupied 2 3 can be adjusted differently for each day of the week if desired If the start time is set later in the day than the stop time the program will run from the start time to midnight and from midnight to the stop time on the same day For example 9 00pm start 8 00am stop ...

Page 13: ...de button for 7 seconds to enter Setup screens If these buttons are released before 7 seconds you will not enter the Advanced Setup screens only Clock Set NOTE Each step is located at the top right corner of the display for easy reference Fan On Fan Auto On Off Tip To change hours quickly press and hold the override button in and press the up or down buttons OVERRIDE MODE MODE MODE MODE MODE I Am ...

Page 14: ...t On or Off Step 6 only appears if heat pump is off in step 4 Adjust the minimum difference between cooling heating setpoints Select the cycles per hour limit d cycles per hour limit defeated d1 d defeat 5 min Compressor lockout Adjust the deadband from 1 6 degrees 0 6 d d1 2 6 B On Off O 81f MODE MODE MODE MODE MODE 0 5 Setup Eh 6 OFF Setup 2 7 Setup 88 2 8 COOL HEAT Setup 6 9 Cy Setup ...

Page 15: ...e blower will run before the Service Filter icon appears on the display 0 off Reset the Service Filter counter to 0 to remove the icon from the display 0 1950 On Off Press OVERRIDE MODE MODE MODE MODE L I I0 ON Setup I i Service Filter Setup 0 I2 Service Filter Setup 500 F I3 Setup Select thermostat operation in degrees Fahrenheit or Centigrade C F ...

Page 16: ...ppears if step 14 is not 0 35 99 MODE MODE O I4 Locked Setup Sec 80 i5 HEAT Locked Setup hi MODE OVERRIDE Adjust the minimum allowable cool setpoint when security is in effect Step 16 only appears if step 14 is not 0 35 99 Press Press the Mode button While holding the Mode press the Override button for 2 seconds to leave the Setup screens If no buttons are pressed the display will leave the setup ...

Page 17: ...rsing Valve polarity O B O 6 Electric Heat Off On Off 7 Deadband or Temperature swing 1 6 2 8 Forced minimum difference heat cool 0 6 2 9 Cycles per hour d d1 2 6 6 10 11 12 13 Thermoglow backlight Off On On Reset Service Filter icon Service Filter run time set 0 1950 500 Fahrenheit or Centigrade F C F 14 Security Levels 0 3 0 15 Maximum allowable Heat setpoint 35 99 80 16 Minimum allowable Cool s...

Page 18: ...ol setpoints will not be allowed to come any closer to each other than the value set in Advanced Setup step 8 on page 13 This minimum difference is enforced during Auto changeover operation and Program On ENERGY SAVING SMART FAN If Fan On is selected page 12 step 3 the fan will run continuously at all times except in Off and will only run if there is a heating or cooling demand in Unoccupied perio...

Page 19: ...re available to Heat Pump installations To turn on Emergency Heat press in the Override button While holding the Override button press the Up button for 2 seconds The Cool setpoint display will read EH During Emergency Heat the thermostat will turn on the fan and the 2nd stage of heat when there is a demand for heat locking out the 1st stage compressor Exiting Emergency Heat is the same as enterin...

Page 20: ...ode button While holding the Mode button in press the Up and Down buttons in together The Locked icon will appear on the display Press all 3 for Keypad Lockout To unlock the buttons again press and hold the Mode button While holding the Mode button in press the Up and Down buttons in together The Locked icon will disappear from the display MODE 85 55 unoccupied On Pm COOL HEAT Locked We I2 00 ...

Page 21: ... to select the number of days the thermostat will be in mode 0 Off To exit Holiday setup the Mode button Holiday press The thermostat will enter the Holiday mode when the clock crosses midnight During Holiday mode Unoccupied setpoints are enforced The Override button is active during Holiday mode It will override to Occupied 1 settings up to 4 hours then return to Holiday mode The Dry Contact Swit...

Page 22: ...to mode from Cool the Heat and Cool setpoints will remain spread apart by the amount that they were adjusted prior to entering Auto For example If the Cool setpoint was set to 80 while in the Cool mode and the Heat setpoint was adjusted to 70 while in the Heat mode upon entering the Auto mode the Heat and Cool setpoints would be 80 and 70 Both setpoints would then move up and down together in this...

Page 23: ... holding the Mode button in press the Down button for 2 sec All icons will appear Press and hold in the Override button until Fd appears This resets all factory settings To calibrate room temperature press the Mode button once more At this point use the Up and Down buttons to calibrate room temperature if needed Press the Mode button to return to normal operation NOTE CAUTION ON PAGE 1 ...

Page 24: ...LL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the installation and servicing instructions or owners manual including filter cleaning and or repla...

Reviews: