background image

 

TROUBLESHOOTING  

If the pump fails to operate: 

  Check to make sure the power cord is plugged in and the pump is getting power. 

  Check the pump outlet and any tubing, fountains, spitters etc. for kinks or obstructions. 

  Remove the inlet screen and/or pump cover, and impeller housing to expose the impeller. Turn 

the impeller to ensure that it is not broken or jammed. 

If the performance of the pump is not satisfactory or the pump does not flow evenly: 

  Check to make sure the pump is completely submerged in water. 

  Check to make sure the impeller and the housing are clean. 

  Adjust flow control.

 

 

REPLACEMENT PARTS LIST  

 

For replacement parts, call our customer service department at 1-888-412-6001, 8 a.m.-6 p.m., EST,  
Monday-Friday. 

 

 
 
 
 
 
 
 

 
 
 
 

 

 
                                                                                                                       

 

 

PUMP PERFORMANCE 

 

 

Flow Rates (GPH) 

L

ift 

fe

et 

12' 

 

 

100 

11' 

 

 

163 

10' 

 

 

220 

9' 

 

 

280 

8’ 

 

70 

338 

7’ 

 

99 

395 

6’ 

79 

198 

449 

5’ 

148 

284 

505 

4’ 

185 

342 

562 

3’ 

219 

395 

618 

2’ 

264 

476 

676 

1’ 

303 

546 

732 

0’ 

337 

560 

793 

  

DD11330 

DD11560 

DD11800 

Pumps 

 

  Printed in China 

Part 

Description 

Inlet screen 

Flow control 

Impeller housing 

Impeller assembly 

O-ring 

 

 

Summary of Contents for DD11800

Page 1: ...k This pump has not been investigated for use in swimming pools or marine areas CAUTION This pump has been evaluated for use with fresh water only Use a proper power source as indicated on the pump label Keep the cord away from high temperatures or other heat sources Do not pump heated liquids Do not let the pump run dry Pump must be completely submerged for proper operation and cooling Operate in...

Page 2: ... into the water and connect to a proper power source Fig 2 Fig 2 3 Adjust the flow control to the preferred setting Fig 3 Fig 3 CARE AND MAINTENANCE Regular cleaning of the pump may be necessary depending upon the environment in which it is operated Clean the pump when it is visibly soiled or when a drop in performance is detected Before cleaning always disconnect the pump from the power source Re...

Page 3: ...es not flow evenly Check to make sure the pump is completely submerged in water Check to make sure the impeller and the housing are clean Adjust flow control REPLACEMENT PARTS LIST For replacement parts call our customer service department at 1 888 412 6001 8 a m 6 p m EST Monday Friday PUMP PERFORMANCE Flow Rates GPH Lift feet 12 100 11 163 10 220 9 280 8 70 338 7 99 395 6 79 198 449 5 148 284 50...

Page 4: ...y does not cover any costs associated with the shipping handling installation or removal of products or parts subject to this warranty For products damaged in transit a claim should be filed with the carrier Disclaimer Any oral statements made about the product by the seller the manufacturer the representatives or any other parties do not constitute warranties should not be relied upon by the user...