NEOREST
®
Installation Instructions <Bowl>
The installation of the toilet bowl for the NEOREST
®
differs from installation
of conventional toilet bowls. Be sure to read the following installation
instructions and install the product only as described in this manual.
✲
Before installation, confirm that the parts listed below are included in the
kit.
Before installing the NEOREST
®
, be sure to read the safety instructions in
"Always Follow This Precaution" and install the product only as described
in the instructions. Precautionary symbols are used in these instructions to
ensure safe and proper installation of the product and to prevent injury to
the end-user and damage to personal property. The definitions of these
precautionary symbols are as follows.
■
Confirm that there is enough floor space to install the toilet unit and
that the bathroom door will open/close without obstruction.
■
Confirm that the position of the drain hole and pipes are properly lined
up as designated in the drawing.
■
Water Pressure.
The NEOREST
®
is designed to operate under a minimum working
pressure of 10 psi flowing. It should be noted that the standard range of
working pressure allowed by model codes is 20 to 80 psi static.*
It is necessary to install the water shutoff valve (angle stop) provided
with the NEOREST
®
. This will assure the proper flow ratio is achieved
and allow for optimum performance of the unit.
*See warranty for details.
There are two types of precautionary symbols. The symbols and definitions
appear below.
When this symbol appears, precaution should be
taken to ensure proper and safe use of the
product. Ignoring this precaution could result in
injury or damage to personal property.
This symbol indicates a
prohibited use of the
product.
Avoid direct impact to the ceramic components as this will break the
ceramic and could result in injury or property damage due to water leakage.
Always use the provided or designated parts for the installation process.
Always Follow This Precaution
Symbol
Definition
WARNING
This symbol means "Always
Follow This Precaution".
WARNING
Parts Included in the Installation Kit
Part Name
Toilet
1
1
Outlet connection
(with rubber joint)
Hex bolts
Mounting plates
Nuts
Washers (for outlet connection)
Self tapping screws (for outlet connection)
Mounting block
Pan head screw
Washers (for mounting block)
Self tapping screws (for mounting block)
Screw cap (front)
Decorative caps (back)
Water shutoff valve
Water supply hose (with gasket)
Connecting hose fastener
Installation manual
Installation template
Water diverter cover (with small screw)
2
2
2
2
4
1
1
2
2
1
1
1
1
2
1
1
1
Drawing
Quantity
Metal Fittings
Decorator
Caps
Water Supply Connectors
Before Installing the NEOREST
®
How to check the water pressure:
If a pressure gauge is unavailable, the fill
method may be used as follows.
The following water volumes will ensure
sufficient water pressure.
Product Diagram
NEOREST
®
water
shutoff valve fully
open condition.
Allow the water to flow into the bucket for
10 seconds and measure the water volume.
Prepare two buckets to
hold the water.
Installation Position
Water volume (for 10 sec)
1.5 Gallons (5.5L) or more
NEOREST
®
water supply valve
fully open condition
0GU9102
H06779R
2006.2
1
2
3
®
15
7
/
8
”
(404mm)
Bathroom
Door
Drain pipe position
(Measuring Procedure)
This manual
Line designating the center of the
toilet bowl
Closet flange
(Not included)
Drain R1/2
11
3
/
4
”
(300mm)
5
7
/
8
”
(150mm)
12
”
(305mm)
5
7
/
8
”
(150mm)
at least 15
3
/
4
”
(400mm)
11
3
/
4
”
(300mm)
26
1
/
4
”
(667mm)
5
7
/
8
”
(150mm)
12
”
(305mm)
Washlet unit water
supply connector
Washlet unit water