VTouch 5-Wires Resistive Touchscreen User Manual
6
A. Resistance between leads
30
Ω
<
X Axis
<
300
Ω
30
Ω
<
Y Axis
<
300
Ω
B. Linearity
X Axis: 3%
↓
Y Axis: 3%
↓
C. C. Insulation Resistance
20M
Ω↑
@ DC25V
2. Low Temperature Test
Put samples in a vessel at the condition of -25
±2˚
C for 120 hours. Then, leave them in a
room temperature for 12hours or more and measure it.
A. Resistance between leads
30
Ω
<
X Axis
<
300
Ω
30
Ω
<
Y Axis
<
300
Ω
B. Linearity
X Axis:
±5%
↓
Y Axis:
±5%
↓
C. Insulation Resistance
20
Ω↑
@ DC25V
3. Humidity Test
Leave samples in an environment of 60
±2˚
C and 90-95% relative humidity for 120 hours
and then perform measurements after putting them at room temperature for 12 hours.
A. Resistance between leads
30
Ω
<
X Axis
<
300
Ω
30
Ω
<
Y Axis
<
300
Ω
B. Linearity
X Axis: 3%
↓
Y Axis: 3%
↓
C. Insulation Resistance
20M
Ω↑
@ DC25V
4. Thermal Shock Test
Put samples in a vessel at the condition of -25
˚
C for 30 minutes and then 70
˚
C for 30
minutes and this process is repeated 20 cycles. Then, leave them in a room temperature
for 24hours or more and measure it.
A. Resistance between leads
30
Ω
<
X Axis
<
300
Ω
30
Ω
<
Y Axis
<
300
Ω
B. Linearity
X Axis: 3%
↓
Y Axis: 3%
↓