tousek
/ E_PASS-838_02 / 22. 10. 2018
- 11 -
1
4E
7
8
2x0,75 mm
2
4x0,75 mm
2
4S
3
5
4x0,75 mm
2
min. 3x1,5 mm
2
2
6
Koaxialkabel
2x0,75 mm
2
Warning note
Please be aware that the above picture is only a symbolic sample illustration
of a gate facility and may therefore not show all safety devices required for
your specific application.
To achieve an optimum safety level at your gate facility, please make sure
that all safety components and accessories which - according to the applying
safety rules and laws - are required in your particular case (e.g. photocells,
induction loops, sensing edges, signal lamps, traffic lights, mains- and emer-
gency power off switches etc.) are properly installed, operated, and serviced.
All possible bruise, shear and general danger areas of the motorised gate
have to be secured.
In this context please follow the EU Machine Directive, accident prevention
rules and laws, as well as applying EU- and national standards in force at the
time of installation and operation of the gate facility.
The Tousek Ges.m.b.H. cannot be held responsible for any consequences
resulting from disregard of applying standards and laws during installation
or operation of the gate facility..
Note concerning cable laying
• The electric cables have to be laid in insulating sleeves
which are suitable for underground usage. The insulating
sleeves have to be lead into the inner of the operator
housing.
• The control lines (buttons, radio, photocells, etc.) have
to be laid separately from the 230V lines (supply line,
motors, signal lamp). and may have a max. length of 50m.
For length > 50m decoupling steps are necessary !
• Only double-insulated cables, which are suitable
for underground usage (e.g. E-YY-J) may be used.
In case that special regulations require another type
of cable, cables according to these regulations have
to be used.
6. Cable plan
Barrier PASS 838
The 0,75mm2 control lines are shown without ground
lead. In order to facilitate connections we recommend
using flexible wires and not using thicker wires for the
control lines.
1
barrier operator Tousek PASS 838
2
electronic logic control with optional available
radio receiver (plugable)
3
main power switch
Note: An all-pole disconnecting main switch with a
contact opening-gap of minimum 3 mm has to be
foreseen
4
photocell (T: transmitter, R: receiver)
5
pushbutton or key-operated momentary contact switch
6
barrier housing signal lamp
7
antenna (connection to radio receiver with coaxial cable)
8
supply with fuse max. 13A