- 20 -
tousek
/ EN_REX-Force_01 / 25. 03. 2020
positioning
automatically
manually
Will disappear after entering,
again selectable either after resetting
or by deleting the positions.
Basic settings
G
identifies the menu items contained in the BASIC SETTING.
main layer
sub layer
settings/adjustments
buttons/switches
page 22
impulse button
OPEN/STOP/CLOSE
OPEN/CLOSE/OPEN
OPEN
DEADMAN
*) if impulse button is set on
DEADMAN, then the pedestrian
and close button are also
set automatically on DEAD-
MAN
mode.
(not selectable under „pedest.-
button“)
pedestr. opening
OPEN/STOP/CLOSE
OPEN/CLOSE/OPEN
OPEN
DEADMAN *)
ILD channel
(ILD = Induction loop detector)
impulse OPEN
security
attendence
security
attendence
photocells
page 24
G
inner photocell
(PHC = photocell)
active
not active
G
outer photocell
active
not active
G
back area photoc.
active
not active
ILD/PHC function inside
during closing reverse
stop, opens after release
during opening stop-then open
ILD/PHC function outside
during closing reverse
stop, opens after release
ILD/PHC pause time
no influence of photocell/ ISD
cancel pause time
re-start pause time
immediate closing after opening
PHC-self test
active
not active
safety edge
page 26
G
safety edge LL1
(LL=left leaf)
not active
opening active
closing active
opening / closing
G
safety edge LL2
not active
opening active
closing active
opening / closing
G
safety edge RL1
(RL= right leaf)
not active
opening active
closing active
opening / closing
G
safety edge RF2
not active
opening active
closing active
opening / closing
SE- status display
status display of the closing edges
left leaf
page 28
G
motor left
motor ON
motor OFF
NO left motor
> select motor OFF
G
delay left leaf
(D= delay)
opening delay
closing delay
G
time delay left
OFF, 1...25s
[ increment 1 ]
= 2s
speed OPEN
30...100%
[ increment 5 ]
= 100%
speed CLOSE
30...100%
[ increment 5 ]
= 80%
soft stop speed
25...75%
[ increment 5 ]
= 50%
soft stop OPEN
OFF, 0,1...5s
[ increment 0,1 ]
= 2s
soft stop CLOSE
OFF, 0,1...5s
[ increment 0,1 ]
= 2s
right leaf
page 28
G
motor right
motor ON
motor OFF
NO right motor
> select motor OFF
G
delay right leaf
(D= delay)
opening delay
closing delay
G
time delay right
OFF, 1...25s
[ increment 1 ]
= 2s
speed OPEN
30...100%
[ increment 5 ]
= 100%
speed CLOSE
30...100%
[ increment 5 ]
= 80%
soft stop speed
25...75%
[ increment 5 ]
= 50%
soft stop OPEN
OFF, 0,1...5s
[ increment 0,1 ]
= 2s
soft stop CLOSE
OFF, 0,1...5s
[ increment 0,1 ]
= 2s
control unit for operator REX Force
+
–
Menu structure
Adjustments - overview