tousek
/ EN_REX-Force_01 / 25. 03. 2020
- 23 -
ILD channel
(N.O. contact, terminals
Z1:
30/39)
Buttons / switches
impulse OPEN ( ):
When driving on the induction loop, the gate opens.
security:
When driving on the induction loop, the setting selected under „ISD/PHC-function“ (
page
25
) is effective.
attendence:
Via a potential free closing contact (terminals
Z1:
78/79), the approach to the induction loop can be
evaluated.
An optionally available induction loop detector forwards the signals of an induction loop
via a potential-free switching contact to the terminals Z1: 30/39.
Further information
corresponding ISD manual.
In traffic light mode only 2 functions are active:
security and
attendence.
39
30
Z1
ISD contact
pedestrian opening
(pedestrian button: NO contact, terminals.
Z1:
30/34)
Buttons / switches
OPEN/ STOP / CLOSE:
After giving a command from the pedestrian opening
button the motor starts with an opening or closing
movement. If the button gets pressed again during this
movement, the motor stops. With the next command the
motor drives in the opposite direction.
OPEN / CLOSE / OPEN:
After giving a command from the pedestrian button the motor starts an opening or closing movement. If the button
gets pressed again during this movement, the motor reverses.
•
In this operation mode it is not possible to stop the motor with the pedestrian button –the gate
always travels up to the end position. (Opened or closed position).
• For the function OPEN/CLOSE/OPEN we strongly suggest the installation of a photocell!
OPEN:
It is only possible to give an opening command by using the impulse switch. Closing the gate with the impulse
switch is not possible.
DEAD-MAN:
The motor opens as long as the impulse switch is pressed – closing the gate with the impulse switch is
not possible. As soon as the switch is released, the gate stops. If hold to run operating mode is selected,
the radio
receiver slot (FE) is set out of order for reasons of safety.
The DEAD-MAN cannot be selected actively but it gets automatically selected when the pulse button
is set to TOTMANN.
pedestrian opening button
(e.g. key switch EPZ 1-1T)
P 1
34
30
Z1
CLOSE-button
(N.O. contact, terminals
Z1:
30/33)
Buttons / switches
• A command with the CLOSE-switch engages closing of gate.
In deadman mode the gate closes as long as the CLOSE-switch is
pressed/switched. As soon as switch is released the gate movement stops.
Impulse OPEN
(N.O. contact, terminals
Z1:
30/36)
Buttons / switches
• With this button only the opening of the gate is possible.
STOP-switch
(N.C. contact, terminals
Z1:
30/31)
Buttons / switches
• when pressing the stop switch the gate stops in
any desired position.
Als Stopp-Taster ist ein Öffnungskontakt zu verwenden.
Wird kein STOPP-Taster ange schlossen, so sind die Klemmen Z1: 30/31 zu brücken.
31
30
The stop input has no emergency stop function! - In order to ensure the emergency stop function, provide
the supply line with an all-pole disconnecting emergency stop switch, that locks after actuation!
CLOSE-button
33
30
Z1
36
30
Z1
Impulse OPEN button
STOP-button
(e.g. switch KDT-1N)
31
30
Z1