- 26 -
tousek
/ EN_REX-Force_01 / 25. 03. 2020
To activate the SYNC-function, the plug-in bridges (J) in both photo
-
cell transmitters have to be removed.
Using two pairs of
photocells with
deactivated SYNC-function, please
do not
install both
photocell transmitters/receivers on the same side
(to eleminate interference between both)!
Inner + outer photocell Tousek LS 41 / LS 180
as safety device
Inner + outer photocell Tousek LS 41 / LS 180
as safety device with active SYNC-function
N.O. COM N.C.
J
J
N.O. COM N.C.
OUTSIDE: transmitter 1
receiver 1
INSIDE: transmitter 2
receiver 2
48
45
46
45
44
43
42
41
Z1
SYNC
J
J
J
N.O. COM N.C.
N.O. COM N.C.
SYNC
J
Z1
48
45
46
45
44
43
42
41
OUTSIDE: transmitter 1
receiver 1
INSIDE: receiver 2
transmitter 2
Safety sensing edges
•
OBSTACLE DETECTION:
When a contact strip is triggered/activated then a change of direction is effected for 1s.
After that the gate stops.
• Activation of the safety edges for the
left motor control ST REX smart
in menu point:
„safety edges | safety edge LL1“
(t.
Z2:
50/52) or
„safety edges | safety edge LL2“
(t.
Z2:
50/53)
and for the
right motor control ST REX smart (Jumper JF
not set = right / set = left)
:
„safety edges | safety edge RL1“
(t.
Z2:
50/52) or
„safety edges | safety edge RL2“
(t.
Z2:
50/53)
• Safety sensing edges on the same door leaf and with the same function (i.e. active when
opening, closing or opening / closing) can be connected in series as shown below.
Example: W
8,2kΩ final resistance
E
final edge
D
passage edge
S
to control ST REX smart (left or right)
When connecting one safety edge a final edge
(E)
has to be used.
safety edge 1
safety edge 2
E
W
D
D
S
50
52
50
53
Z2 of
ST REX
smart 1
safety edge 1
safety edge 2
Z2 of
ST REX
smart 2
50
52
50
53
Safety edges
Connections and adjustments