- 28 -
tousek
/ EN_REX-Force_01 / 25. 03. 2020
G
motor left
Left leaf
Motor ON
Motor OFF:
no left motor.
G
delay left leaf
Left leaf
opening delay:
the left leaf opens after the adjusted delay time.
closing delay
:
the left leaf closes after the adjusted delay time.
G
time delay left
2s (factory settiing)
Left leaf
OFF, 1–25s adjustable [increment 1]:
indicates the delay time at opening or closing.
speed OPEN
100% (factory settiing)
Left leaf
30–100% adjustable [increment 5]:
determines the speed of motor in opening direction.
speed CLOSE
80% (factory settiing)
Left leaf
30–100% adjustable [increment 5]:
determines the speed of motor in closing direction.
soft stop speed
50% (factory settiing)
Left leaf
25–75% adjustable [increment 5]:
determines the speed during soft run. If the entered value for soft speed is
higher than normal speed the value will be rejected and automatically set to a value that is 5% below the set value
for normal speed.
soft stop OPEN
2s (factory settiing)
Left leaf
OFF, 0,1–5s adjustable [increment 0,1]:
determines soft stop time in opening direction.
soft stop CLOSE
2s (factory settiing)
Left leaf
OFF, 0,1–5s adjustable [increment 0,1]:
determines soft stop time in closing direction.
Left
leaf
Connections and adjustments
Attention
With speed adjustment the valid safety regulations and standards have to be strictly followed (
Kinetische Energie
) !
G
motor right
Right leaf
Motor ON
Motor OFF:
no right motor.
G
delay right leaf
Right leaf
opening delay:
the right leaf opens after the adjusted delay time.
closing delay
:
the right leaf closes after the adjusted delay time.
G
time delay right
2s (factory settiing)
Right leaf
OFF, 1–25s adjustable [increment 1]:
indicates the delay time at opening or closing.
speed OPEN
100% (factory settiing)
Right leaf
30–100% adjustable [increment 5]:
determines the speed of motor in opening direction.
speed CLOSE
80% (factory settiing)
Right leaf
30–100% adjustable [increment 5]:
determines the speed of motor in closing direction.
soft stop speed
50% (factory settiing)
Right leaf
25–75% adjustable [increment 5]:
determines the speed during soft run. If the entered value for soft speed is
higher than normal speed the value will be rejected and automatically set to a value that is 5% below the set value
for normal speed.
soft stop OPEN
2s (factory settiing)
Right leaf
OFF, 0,1–5s adjustable [increment 0,1]:
determines soft stop time in opening direction.
soft stop CLOSE
2s (factory settiing)
Right leaf
OFF, 0,1–5s adjustable [increment 0,1]:
determines soft stop time in closing direction.
Right
leaf
Connections and adjustments