tousek
/ EN_REX-Force_01 / 25. 03. 2020
- 29 -
impulse logic
Operating mode
stop, start of pause time:
An impulse during the opening movement stops the gate and starts pause time in automatic
operation. When the pause time has run out, the gate closes automatically.
impulse suppressioning when opening:
Commands received during the opening movement are suppressed,
commands during closing are accepted.
In traffic light mode automatically „impulse suppressioning when opening“ is active.
pause time extension:
A command during pause time restarts the pause time. If this menu point is chosen, an impulse
suppression during opening is active at the same time.
G
operating mode
Operating mode
impulse mode:
Impulse through impulse switch/button or CLOSE-button to start closing of gate.
1–255s automatic close adjustable [increment 1]:
gate closes automatically after the adjusted pause time.
pedestr. opening
100% (factory setting)
Operating mode
25–100% adjustable [increment 1]:
value defines the partial opening based on the total opening.
In traffic light mode this setting has no influence.
This adjustment is ONLY adopted in CLOSED-position.
automatic mode
Operating mode
complete / pedestrian opening:
either with complete as well as partial opening, the gate closes automatically after
the adjusted pause time.
only complete opening:
only after complete opening, the gate closes automatically after the adjusted pause time.
In traffic light mode automatically „
only complete opening“ is active.
only pedestrian opening:
only after partial opening the gate closes automatically after the the adjusted pause time.
pause time logic
Operating mode
no influence
In traffic light mode automatically „no influnce
“ is active.
permanent ON:
if this function is activated, the control unit goes from automatic mode into impulse mode
with activated
pause time through impulse in open gate position
for this cycle , hence if gate is open then an impulse will end the
automatic mode - the gate remains open. Only the next impulse will close the gate and the control unit goes back to
automatic mode. With this function e.g. the entrance to a company site can remain open during the day (1st impulse
in gate open position) and closed in the evening (2nd impulse). The control board switches back to automatic mode
(autom. opening and closing of gate).
acceleration time
3s (factory setting)
Operating mode
1,0–9,9s adjustable [increment 0,1]:
Time of motor acceleration from 0 to „speed OPEN (CLOSE)“
lighting 10s
(terminals
Z1:
10/11)
Operating mode
not active
active:
lighting output (terminals
Z1:
10/11) is active,
e.g. for lighting of the gate for the duration of the mo
10 seconds.
Operating
mode
Connections and adjustments