Important: Mounting position of the operator
• The mounting position of the REX operator must be selected according to the given door situation and the
planned opening angle of the door:
!
When planning or installing the operator make sure that there is a sufficient space for the gate and the motor
arm (2) even in the open position of the gate.
!
It is essential to note the dependence of the mounting position of the operator on the planned opening angle of
the door so that a collision between the door and the operator when opening is excluded. Futhermore sufficient
space for the installation of safety edges must be available to secure safety-relevant points. The safety edge
must not be triggered by an operator arm or the gate itself.
see also installation examples page 9–11
2. Mounting
REX Force
General installation instructions
• The operator REX force is equipped with internal limit stops which are used to set the end positions OPEN and CLOSE.
These can be used for gates up to a
max. wing width of 6m and a max. gate weight of 700kg.
For gates that exceed these values, external limit stops with sufficient dimensions must be provided
!
• *) Attention: In order to avoid soiling and to ensure a permanently reliable operation, a minimum distance of
500mm
to the upper edge of the roadway should be maintained.
!
!
(1)
Motor console
(2)
Motor arm
(3)
Elbow
(4)
Gate arm
(5)
Gate console
(S1)
Safety edges
Danger !
• Please note that moving machine parts and gate systems
form danger spots.
• Therefore set up protective measures to safeguard the
danger points: Anti-trap protection using safety edges
(S1).
• Please observe the valid standards and guidelines
when setting up automatic gate systems!
*) min. 500mm
!!
5
!
!
4
S1
S1
2
3
1