- 6 -
tousek
/ E_LWA-115/1A_40800708 / 29. 10. 2018
50mm
97mm
Important
• the cantilever track and gate frame have to be connected together in a stable way!
Version: T-head bolts
Version: Through bolts
2a. Mounting gate frame on Rollco
®
LWA 115/1A
Mounting
Examples for mounting the gate frame on Rollco
®
LWA 115/1A
(6)
profile
(TR)
gate frame
• Recommended dimensions for aluminium gate frame: steel profile 80/60/2,5mm, on edge.
• In the area of the support length the gate frame should be furthermore equipped with a diagonal
tie, and for an overall length of 5 m and more, a turnbuckle has to be foreseen.
• Starting from a clearance width DL of 3 m, the gate frame should at least be parted in 2 sections
and equipped with diagonal ties. Further important notes
(see page 4).
• These values are only standard values, the gate frame has to be designed according to the static
requirements.
• The gate frame is fixed with T-head bolts, at the ends of the gate frame the double T-head bolts
are inserted.
• The fixation of the ends should be carried out as far on the ends of the gate frame as possible.
• The gate frame should generally be fixed in distances of max. 500 mm.
80 2,5
60
distance Ø15/2
welded-in
M10
The gate frame is screwed every 500 mm, at the ends of the frame the double
T-head bolts are used, everywhere else the single ones.
T-head bolts (M10, single
and double) are inserted
in the foreseen guiding at
the profile.
TR
500mm
500mm
500mm
6
TR
6
distance Ø15/2
welded-in
M10
14,5
max. 12
Allen srews
TR
6
screwed all 500mm