background image

- 6 - 

tousek

  /  E_LWA-115/1A_40800708  /  29. 10. 2018

50mm

97mm

 Important

•  the cantilever track and gate frame have to be connected together in a stable way! 

 

 

Version: T-head bolts

 

Version: Through bolts

 

2a.  Mounting gate frame on Rollco

®

 LWA 115/1A 

Mounting

Examples for mounting the gate frame on Rollco

®

 LWA 115/1A

(6)

  

profile

 

(TR)

  

gate frame

•  Recommended dimensions for aluminium gate frame:  steel profile 80/60/2,5mm, on edge. 

•  In the area of the support length the gate frame should be furthermore equipped with a diagonal 

tie, and for an overall length of 5 m and more, a turnbuckle has to be foreseen. 

•  Starting from a clearance width DL of 3 m, the gate frame should at least be parted in 2 sections 

and equipped with diagonal ties. Further important notes  

(see page 4).

•  These values are only standard values, the gate frame has to be designed according to the static 

requirements. 

•  The gate frame is fixed with T-head bolts, at the ends of the gate frame the double T-head bolts 

are inserted.

•  The fixation of the ends should be carried out as far on the ends of the gate frame as possible. 

•  The gate frame should generally be fixed in distances of max. 500 mm.

80 2,5

60

distance Ø15/2

welded-in

M10

The gate frame is screwed every 500 mm, at the ends of the frame the double  

T-head bolts are used, everywhere else the single ones.

T-head bolts (M10, single 

and double) are inserted 

in the foreseen guiding at 

the profile.

TR

500mm

500mm

500mm

6

TR

6

distance Ø15/2

welded-in

M10

14,5

max. 12

Allen srews

TR

6

screwed all 500mm

Summary of Contents for Rollco LWA 115/1A

Page 1: ...Installation and operating instructions Aluminium cantilever system Rollco LWA 115 1A...

Page 2: ...iding elements etc are sufficiently supportive and resistant for the purpose of gate automation Check also whether the product has transport damages After installation the proper function of the gate...

Page 3: ...support roller 4b back limit stop with rubber bumper 5a T head bolts single 5b T head bolts double 6 profile 7a b front back rolling gear and mounting plate in stainless steel 8 rolling gear cover 9...

Page 4: ...support roller and a guide in bracket have to be mounted in position gate CLOSED For the upper gate guiding a guide bracket with rollers and a guide in fork bracket have to be foreseen in gate positio...

Page 5: ...ing plate sliding gate operator center of cantilever system min 110 1 mounting plate guidance of gear rack foundation 12 5 350 380 116 5 120 85 55 273 M10 32 2 Mounting Aluminium cantilever system Rol...

Page 6: ...d at least be parted in 2 sections and equipped with diagonal ties Further important notes see page 4 These values are only standard values the gate frame has to be designed according to the static re...

Page 7: ...has to made sure that both rolling gears are standing in line e g by applying an aluminium lath Now bore the holes blow them out and drive in the heavy duty anchors Do exclusively use the supplied hea...

Page 8: ...the rubber bumpers show in direction of the rolling gears Vertical adjustment of the rolling gears A Drive gate in positon CLOSED and with adjusting bolt JS put up the indicated roller of the rear rol...

Page 9: ...assembly of the end plates it has to be taken care that they are executed in different ways The front end plate 1a has two plastic guidings at the sides and has to be mounted at the side of the profil...

Page 10: ...o be sequentially lead in the foreseen guiding at the profile It has to be taken care that they touch each other without gaps The two clampings 3 serve as fixation of the gear rack they are also lead...

Page 11: ...A 115 1A guide in bracket Rollco LWA 115 1A 20 25 35 77 30 77 82 5 103 5 145 96 5 85 5 120 Profile length 6 000mm 10mm 8 000mm 10mm 105 70 134 108 14 5 3 Dimensioned drawing Aluminium cantilever syste...

Page 12: ...7 Tel 48 32 738 53 65 Fax 48 32 738 53 66 info tousek pl Tousek s r o Czech Republic CZ 130 00 Praha 3 Jagellonsk 9 Tel 420 2 2209 0980 Fax 420 2 2209 0989 info tousek cz We reserve the right to chang...