- 14 -
tousek
/ EN_ST-12-5_05 / 25. 03. 2020
Warning
•
Before taking off the housing cover the
main switch has to be turned off !
•
IMPORTANT:
At force adjustment
(see Left(Right)
wing)
the valid safety regulations and standards
have to be strictly followed!
•
Follow safety instructions
(see page 8)
!
CONNECTION OF MOTORS
MR
motor
(left leaf)
motor
(right leaf)
blue *)
brown
*)
blue *)
brown *)
ML
20 21 24 25
Important: notes for connection and adjustment of operators
• It is possible to connect
2 motors 12V DC, max. 60 W
to the control board ST 12/5.
Motor left: terminals 20/21 / Motor right: terminals 24/25
•
Attention: Before carrying out any installation and connection works, the power supply of the gate facility has
to be turned off!
•
Connection: When connecting the operators to the control unit, always pay attention to the door situation, ie
whether the door opens inwards or outwards (= special case). The drive connection
(see table)
and the function
of the limit switches
(see operator manual)
are dependent on this.
Door situation
*) opening inwards
special case:
opening outwards
Motor
LEFT
RIGHT
LEFT
RIGHT
blue cable
to terminal:
20
24
21
25
brown cable
to terminal:
21
25
20
24
left motor
INSIDE
right motor
special case: opening outwards
left motor
right motor
INSIDE
*)
opening inwards
•
IMPORTANT: At operation with a single motor, the other motor input has to be deactivated by choosing
„MOTOR OFF“. If the LEFT (RIGHT) wing is set to OFF in the menu, no motor may be connected with the
concerned wing.
•
OBSTACLE DETECTION:
If a gate wing runs into an obstacle a change of direction is effected for 1 second.
Then the gate stops.