Left leaf
motor ON
motor OFF
G
delay left leaf
Linker Flügel
opening delay:
The leaf opens against the right one only after a set delay time.
closing delay:
The leaf closes against the right one only after a set delay time.
G
delay time left
2s (factory setting)
Left leaf
0–25s delay time adjustable:
defines the delay during opening or closing.
ARS response time
0,70s (factory setting)
Left leaf
0,15–0,95s ARS response time adjustable:
defines, in what time the AR-system responds. The lower the value the
more sensitive the system is set.
max. force
70% (factory setting)
Left leaf
30–100% adjustable:
determines the motor force
soft stop time
5s (factory setting)
Left leaf
0–25s adjustable:
defines the duration of soft stop phase.
left motor
INSIDE
Left leaf
Connections and adjustments
right motor
Important
• the adjustment has to match the actual situation of
the motor connection !
motor right
(terminals 24/25)
Right leaf
motor ON
motor OFF
G
delay right leaf
Linker Flügel
opening delay:
The leaf opens against the left one only after a set delay time.
closing delay:
The leaf closes against the left one only after a set delay time..
G
delay time right
2s (factory setting)
Right leaf
0–25s delay time adjustable:
defines the delay during opening or closing.
ARS response time
0,70s (factory setting)
Right leaf
0,15–0,95s ARS response time adjustable:
defines, in what time the AR-system responds. The lower the value the
more sensitive the system is set.
max. force
70% (factory setting)
Right leaf
30–100% adjustable:
determines the motor force
soft stop time
5s (factory setting)
Right leaf
0–25s adjustable:
defines the duration of soft stop phase.
Right leaf
Connections and adjustments
Important
• the adjustment has to match the actual situation of
the motor connection !