- 12 -
tousek
/ EN_ST-63_02 / 25. 03. 2020
–
ESC
ENTER
+
text display
•
The program menu is divided into „POSITIONING“ „BASIC SETTINGS” and „ MENU CONTROL”
BASIC SETTINGS
•
When entering the programming of the control unit for the first time you will see the BASIC SETTINGS
.
• Here the necessary adjustments for the use of the operator/gate can be set quickly.
• For advanced settings/programming please choose the menu point „menu control”.
MENU CONTROL
• For futher programming you will reach immediatly the MENU (CONTROL) (Basic settings are skipped)
• The menu control includes all kinds of settings.
The different menu points are indicated as follows:
= selectable settings
= factory settings
= status display
G
shows the menu points which are in the “ BASIC SETTINGS”
Programming menu
Adjustments - overview
2.5 Programming
ST 63 control unit for folding and swing gates
Programming buttons
Adjustments - overview
•
The adjustment (programming) of the operating parameters is carried out with four programming buttons and
the display.
•
Before starting the programming, please choose the language. Use the buttons
+
or
-
to choose menu langua-
ge and confirm with
ENTER.
• Note: Language selection can also be chosen by pressing the ESC button for 5s, from any position in menu
.
•
Before the programming can be started, you have to select the door type (swing gate or folding gate)
• The text display informs about behaviour, chosen menus
and adjustment of different settings.
• The programming of the control is carried out with the help
of four buttons
(+, -, ENTER and ESC).
• Scrolling through the available menu points (up/
down) or the adjustment of a parameter (value in
-
crease/decrease) is carried out with buttons
+
and
–
..
AUTO-COUNT:
when holding one of the buttons the value
changes automatically.
• When pressing the
ENTER
-button a confirmation for
entering the shown menu point, resp. for accepting the
shown value of a parameter is given.
• When pressing the
ESC
-button you return to the superior
menu point. Possibly changed adjustments of a parameter
are rejected with this button (the former values will remain).
•
AUTO-EXIT:
if no button is pressed during 1 min. then the
menu switches automatically to the “ready” menu (wihtout
saving changed parameters)