- 22 -
tousek
/ EN_ST-63_02 / 25. 03. 2020
impulse logic
Operating mode
stop, start of pause time:
An command by impulse button during the movement stops the gate and starts pause time
in automatic operation. When the pause time has run out, the gate closes automatically.
impulse suppressioning:
Commands received during the opening movement are suppressed, commands during
closing are accepted.
In traffic light mode automatically „impulse suppressioning“ is active.
pause time extension:
A command during pause time restarts the pause time. If this menu point is chosen, an impulse
suppression during opening is active at the same time.
G
operating mode
Operating mode
impulse mode:
Impulse through impulse button or CLOSE-button to start closing of gate.
1–255s automatic close adjustable [increment 1]:
gate closes automatically after the adjusted pause time.
pedestrian opening
100% (factory setting)
Operating mode
25–100% adjustable [increment 1]:
value defines the partial opening based on the total opening.
In traffic light mode this setting has no influence.
This adjustment is ONLY adopted in CLOSED-position.
automatic mode
Operating mode
complete / pedestrian opening:
either with complete as well as partial opening, the gate closes automatically after
the adjusted pause time.
only complete opening:
only after complete opening, the gate closes automatically after the adjusted pause time.
In traffic light mode automatically „
only complete opening“ is active.
only pedestrian opening:
only after partial opening the gate closes automatically after the the adjusted pause time.
pause time logic
Operating mode
no influence
In traffic light mode automatically „no influence
“ is active.
permanent ON:
if this function is activated, the control unit goes from automatic mode into impulse mode
with activated
pause time through impulse in open gate position
for this cycle , hence if gate is open then an impulse will end the
automatic mode - the gate remains open. Only the next impulse will close the gate and the control unit goes back to
automatic mode. With this function e.g. the entrance to a company site can remain open during the day (1st impulse
in gate open position) and closed in the evening (2nd impulse). The control board switches back to automatic mode
(autom. opening and closing of gate).
Operating
mode
Connections and adjustments
The ramp time determines the acceleration (zero to adjusted speed) as well as the stopping (adjusted speed to zero) of the
gate. The higher the adjusted ramp time is the slower is the acceleration and the stopping of the gate.
ramp time open
3s (factory setting)
only with folding gate
Operating mode
1,0–6,0s adjustable [increment 0,1]:
ramp time when gate opens.
ramp time close
3s (factory setting)
only with folding gate
Operating mode
1,0–6,0s adjustable [increment 0,1]:
ramp time when gate closes.