Installation and connection manual

Barrier control unit ST 80A, ST 80VA

in combination with traffic light control STA 11 

Summary of Contents for ST 80A

Page 1: ...Installation and connection manual Barrier control unit ST 80A ST 80VA in combination with traffic light control STA 11...

Page 2: ...terminals 45 46 16 Photocells connection examples 16 17 G Main closing edge terminals 50 52 18 PHC ISD function 18 PHC ISD pause time 18 PHC test 18 Motor 19 max force 19 ARS response time 19 Speed OP...

Page 3: ...on and operating instructions The TOUSEK Ges m b H rejects any liability if the product is used in any way not fully conforming to its original purpose as stated herein Children have to be instructed...

Page 4: ...l radio receivers and induction loop detector Operator control board ST 80 V A Traffic light control board STA 11 General For the implementation of the traffic light system the traffic light control b...

Page 5: ...ED 2 opening command INSIDE or OUTSIDE RED RED Prewarning OPEN is being started red traffic light warning and possibly signal light warning before opening the door gate duration adjustable via gate au...

Page 6: ...mand FE Slot for optional radio receiver p 8 F fuse 3 15A T Warning Before opening the control board box please switch off necessarily the main switch In supplied control inside the unit is powered th...

Page 7: ...rator control board see operator control board 97 6 99 6 96 6 98 6 GREEN outside RED outside GREEN inside RED inside Traffic light outputs outside GREEN term 97 6 RED term 99 6 inside GREEN term 96 6...

Page 8: ...raffic light control board STA 11 Important With the use of the 2 channel receiver the first chan nel takes over the function for the impulse switch outside and the second channel the function for the...

Page 9: ...tousek EN_ST 80A_04 25 03 2020 9...

Page 10: ...op fu Without function in connection with traffic light control board ZM Slot for optional module Status display p 24 T Transformer F1 safety fuse F 5A F2 safety fuse F 2A 3 Barrier control board ST 8...

Page 11: ...e turned off If the control is power supplied its inner part is under tension In order to avoid electrical strokes the safety regulations have to be respected The device may only be connected by train...

Page 12: ...value of a parameter is given When pressing the button you return to the superior menu point Possibly changed adjustments of a parameter are rejected with this button the former values will remain AU...

Page 13: ...g only with ST 80VA active not active lights lamps see page 20 prewarning OPEN OFF 1 30s OFF Green phase 5 120s increment 1 20s Clearance time 1 60s increment 1 5s Traffic light gate CLOSED OFF consta...

Page 14: ...o be kept The device may only be connected by trained profes sionals Theproductisnotsuitableforinstallationinexplosion hazardous areas Anall poledisconnectingmainsswitchwithacontact opening gap of min...

Page 15: ...unction of I loops has to be selected under ISD channel 1 and ISD channel 2 I loops can be connected onto the traffic light control board STA 11 as command transmitters For this the STA 11 has also to...

Page 16: ...uencies Photocell self test function The control board is equipped with a self test function for the connected photocell With an opening impulse switch or button the transmitter of the photocell is sw...

Page 17: ...upport SYNC function the photocell transmitters and receivers have to be mounted on different sides 2 Photocells Tousek LS 45 2 as safety device Photocells Tousek RLS 620 as safety device 24Va c 12 24...

Page 18: ...uption of the photocell induction loop during closing makes the barrier reverse open In automatic mode the barrier closes as soon as the pause time has run out In impulse operation another closing com...

Page 19: ...able increment 5 determines the max possible motor force ARS response time 0 5s factory setting Motor 0 15 0 95s closing speed adjustable increment 0 05 determines in which time the AR System responds...

Page 20: ...0 11 Light Lamps turned off 1 30s adjustable Before each opening movement the signal lamp flashing light is activated for the adjusted time Boom lamp CLOSE terminals 70 71 Light Lamps The boom lamp bl...

Page 21: ...y of the optional module in control unit ST 80 V A p 24 Max contact load 1A 24Va c d c Signal contacts Description status display module see page 24 Peripherals Status display 1 with the two potential...

Page 22: ...ES reset back to factory settings and delete the adjusted limits The end posistions limits will be redetermined after impulse Software version control function Reset Diagnosis shows the software versi...

Page 23: ...perator control board ST 80 V A the I loop function depends on the settings under buttons switches ISD channel 1 2 safety PHC ISD function and safety PHC ISD pause time Detailed informations can be fo...

Page 24: ...under Peripherals Signal contacts p 21 Connection the module Turn off the power supply Plug in the status display module into the slot ZM With the potential free signal contacts K1 term 90 91 and K2 t...

Page 25: ...ell active Main safety edge active Photocell not active Main safety edge not active change YES confirm change YES confirm BASIC SETTINGS For setting the most important adjustments for initial operatio...

Page 26: ...bstacle or is too hard to move check adjustment of forces remove obstacle hence check if boom is easy to move Display photocell test negative interruption or hot wired photocell check correct connecti...

Page 27: ...ek EN_ST 80A_04 25 03 2020 27 Dimensions in mm We reserve the right to change dimensions and technical specifications without prior notice 240 195 Depth 105 8 Dimensioned drawing of housing IP54 ST 80...