tousek
/ EN_ST-80A_04 / 25. 03. 2020
- 13 -
Main menu
Sub layer
Settings/adjustments
buttons/switches
see page 15
ISD channel 1
no function
safety
attendance
ISD channel 2
no function
safety
attendance
safety
see page 16–18
G
photocell
active
not active
G
main safety edge
active
not active
PHC/ISD function
reverse during closing
during closing stop, then close
PHC/ISD pause time
no influence
immediate closing after opening
PHC selftest
active
not active
motor
see page 19
ST 80A
ST 80VA
max. force
50...100% [increment 5]
= 100%
= 100%
ARS-response time
0,15...0,95s [increment 0,05]
= 0,50s
= 0,50s
speed OPEN
55...100% [increment 5]
= 90%
= 100%
speed CLOSE
55...100% [increment 5]
= 90%
= 100%
soft stop way
0...5s
[increment 0,1]
= 1,5s
= 1s
operating mode
see page 19
impulse mode
without pause time extension
forced closing
(only with ST 80VA)
active
not active
lights/lamps
see page 20
prewarning OPEN
OFF, 1...30s
= OFF
Green phase
5...120s
[ increment 1 ]
= 20s
Clearance time
1...60s
[ increment 1 ]
= 5s
Traffic light gate CLOSED
OFF
constant red
Traffic light logic
both side green
one side green
boom lamp CLOSE
OFF
blinking
illuminates
peripher. devices
see page 21
signal contacts
status display 1
status display 2
magnetic clamp
OFF, 0,1...1,0s
= OFF
diagnosis
see page 22
status display
status dispaly of all inputs
delete positions
NO
YES
factory settings
NO
YES
software version
display software version
serial number
display serial number
protocol
display protocol messages
sensor status
display sensor
Menu structure
+
–
Barrier control unit ST 80(V)A
ESC
ENTER
Note:
some
adjustments
regarding
function
or
operating
logic
can
only
be
executed
if
barrier
is
closed
and
if
the
display
shows
„ready“.
At barriers with 6m boom length the settings for speed OPEN/CLOSE must not be more than
90% (= factory setting of ST 80A)!