tousek
/ EN_TPS-60-PRO_05 / 25. 03. 2020
- 17 -
As pedestrian button you can use pushbuttons or key switches as well as external radio receivers with potential
free make contacts can be used.
Pedestrian button
(terminals X1: 30/34)
Buttons / switches
OPEN/ STOP / CLOSE impulse repetition:
After a command of the pedestrian opening button the
motor for pedestrian opening starts with an open- or
closing movement. If the button is pressed again during
this movement, the motor stops. With the next command
the motor drives in the opposite direction of the last gate
movement.
OPEN / CLOSE / OPEN impulse repetition:
after a
command of the pedestrian opening button the motor
starts an open or close movement. If the button is pressed
again during this movement, the motor reverses.
•
In this operation mode it is not possible to stop the motor with the pedestrian button – it always
travels until reaching an end position. (Opened or closed position).
• for the function OPEN/CLOSE/OPEN we strongly suggest the installation of a photocell!
OPEN:
Only open commands are accepted of the pedestrian opening button. Closing the pedestrian entry with the
button is not possible.
Impulse OPEN:
The contact at terminals X1: 30/34 works as a second impulse button with the fixed adjustment „OPEN“.
DEADMAN:
The motor opens as long as the pedestrian button is pressed – closing the gate
with the pedestrian button is not possible. As soon as the switch is released, the gate stops.
As soon as DEADMAN is selected, the radio receiver is without function for safety reasons.
The DEAD MAN setting cannot be actively selected, but it gets automatically selected when the impulse
button is set on DEAD MAN.
pedestrian opening button
(e.g. key switch EPZ 1-1T)
As CLOSE-buttons you may use pushbuttons or
key switches as well as external radio receivers
with potential free make contacts can be used.
CLOSE- button
(terminals X1: 30/33)
Buttons / switches
• A command with the CLOSE-switch engages clo-
sing of gate. In deadman mode the gate closes as
long as the CLOSE-switch is pressed/switched.
As soon as switch is released the gate movement stops.
CLOSE-button
(e.g. key switch EPZ 1-2T)
P 1
34
30
X1
2 P 1
33
30
X1
STOP-button
(terminals X1: 31/37)
Buttons / switches
• When pressing the stop switch the gate stops in any
desired position.
As stop switch a break contact has to be used.
If no stop switch is connected, terminals X1: 31/37 have to be wire-bridged.
37
31
X1
The stop input has no emergency stop function! - In order to ensure the emergency stop function, provide
the supply line with an all-pole disconnecting emergency stop switch, that locks after actuation!
STOP-button
(e.g. switch KDT-1N)
X1
37
31