- 28 -
tousek
/ EN_TPS-60-PRO_05 / 25. 03. 2020
6. Putting into operation
Sliding gate operator TPS 60 PRO
Important: preparation works
• Connect control panels, safety devices to the motor under the safety regulations in .
Attention: if no stop switch is connected then the terminals 31/37 have to be bridged.
•
The mechanical limits have to be placed so that contact edges are not triggered, as this would lead to an error
message
• Unlock with emergency release ( see page 30) and set gate to half-opened position-Then lock the operator again.
• Then re-engage operator (correct connection necessary).
•
Important:
Putting into operation in Impulse mode (standard setting) and not in dead man mode.
• During initial operation the choice of language is made first, then in the “Basic settings” the adjustment of most impor
-
tant operator settings and after the system test, the automatic detection of limit positions of gate is made.
•
IMPORTANT:
After giving the impulse to program the end positions, no other impulse must be given. Also the safety
devices mustn´t be triggered. This would lead to an interruption of the programming process.
Note: during operation with the basic setting for limit positions OPEN/CLOSE (=-5), the limit stops will not be
reached (only with adjustment = 0)
Factory settings
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
Language:
English
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
Tousek Vx.x
TPS60PRO
2
1
2
3
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
Basic settings
scroll
confirm
confirm
LANGUAGE SELECTION
•
Can be selected during initial operation (hence after reset to factory settings).
•
Can be also chosen by pressing the ESC button
(
)
for 5s, from any position in menu.
BASIC SETTINGS
•
For setting the most important adjustments for initial operation of motor.
•
Can be selected during initial operation (hence when restoring the factory setting).
•
All safety devices are activated when leaving factory
(see menu page 15).
•
The next programming adjustments are made in the main settings menu
(see page 14, 15).
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
Photocell
3
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
Photocell
active
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
Photocell
not active
change? YES
confirm
LS
3
4
LS